Problem
Motor does not start
Loud noise
Motor stops
No Suction
No output
Insufficient pressure
Unstable water output
Nozzles dripping
Possible Causes
No power supply
Low Voltage
Insufficient water pressure
Unsteady power supply
Air in pumps
Water supply interrupted
Motor overload
Air in the pump or hose
Clogged nozzles or filter
Damaged pump
Nozzles worn out
Damage to pump or pressure
release valve
Too many nozzles in use
Mist line is too long
Clogged nozzles or filter
Air in pump
Damage to pump or pressure
release valve
Pressure release interval too
short
Recommended Action
Check power cable and power supply
Confirm voltage
Check water inlet for obstructions
Check power supply
Check the inlet hose and filter
Check water supply
Confirm voltage
Press reset button on motor
Press air release button
Unfasten pump outlet, let water run 2 to
3 minutes
Clean nozzles and filer
Return pump for repair
Replace nozzles
Return system for repair
Reduce the nozzles to ones with smaller
orifice
Reduce length of mist line
Press air release button
Unfasten pump outlet, let water run 2 to
3 minutes
Clean nozzles and filter
Check the inlet connections
Gradually adjust pressure release setting
to longer interval