Burda PERFECTCLIME PCE05 Montage Et Mode D'emploi page 11

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

S
T
S
A
S
ETTING
HE
PRAY
ND
TOP INTERVAL
[Example] How to make the "Spray 3 minutes and stop 50
How to make the "Spray 3 minutes and stop 50
seconds" setting:
Setting the spraying time:
• Use the "Spray Time Setting Dial" and turn it to 3
• Use the "Spray Time Setting Dial" and turn it to 3
• Set the switch to "M" which is left of "Spray Time Setting
• Set the switch to "M" which is left of "Spray Time Setting
Dial"
• Set the switch to "1" to get one time setting
witch to "1" to get one time setting
The system will spray for 3 minutes.
• Possible time setting min. 15 sec. max. 60 m
in. 15 sec. max. 60 min.
Setting the stop spraying time:
• Use the "Stop Spraying Setting Dial" and turn it to 5.
• Use the "Stop Spraying Setting Dial" and turn it to 5.
• Set the switch to "S" which is left of "Stop Spraying
Setting Dial".
• Set the switch to "10" to get ten times setting.
• Set the switch to "10" to get ten times setting.
The system will remain stopped for 50 seconds
The system will remain stopped for 50 seconds.
• Possible time setting min. 15 sec. max. 60 m
in. 15 sec. max. 60 min.
Setting the Pressure Release Time:
• The maximum pressure release time is 15 seconds.
release time is 15 seconds.
• The stop spraying time must be longer than pressure
The stop spraying time must be longer than pressure
release time in order to make sure the two actions do not
release time in order to make sure the two actions do not
overlap.
• The longer misting line, the more pressure release time is
• The longer misting line, the more pressure release time is
needed.
• Every time the pump stops a signal from the timer will
Every time the pump stops a signal from the timer will
cause the pressure release solenoid valve to open,
cause the pressure release solenoid valve to open,
depressurizing the mist line.
• The benefit of this is reducing the water dripping from the
The benefit of this is reducing the water dripping from the
nozzles. The setting of this knob determines the duration of
nozzles. The setting of this knob determines the duration
that signal and how long the valve stays open.
that signal and how long the valve stays open.
• There are several factors which affect the residual
There are several factors which affect the residual
pressure in the mist line, so the setting of that dial might
pressure in the mist line, so the setting of that dial might
need adjustment.
• The best bet is to start by setting dial to 5 seconds.
The best bet is to start by setting dial to 5 seconds. - If the
nozzles still spray and drizzle when the pump stops,
nozzles still spray and drizzle when the pump stops,
increase the time the on dial to let more pressu
increase the time the on dial to let more pressure escape
when the pump stops.
• If there is a long delay between when the pump starts and
If there is a long delay between when the pump starts and
when the nozzles begin to spray, decrease the time on the
when the nozzles begin to spray, decrease the time on the
dial, as the system is not keeping enough pressure in the
as the system is not keeping enough pressure in the
mist line and it takes longer for the pump to fully
mist line and it takes longer for the pump to fully
depressurize the line each time the pump starts.
depressurize the line each time the pump starts.
• Some factors affecting the time required here are the
Some factors affecting the time required here are the
material of the mist line, length of the mist line, number of
nozzles, and strength of the springs in the anti
nozzles, and strength of the springs in the anti-drip valves
inside the nozzles.
• Turning On / Off the Misting System
• Press the power switch "On" & "Off" to start & stop
• Press the power switch "On" & "Off" to start & stop
machine.
5. Pump stop running without water
• The "On" & "Off" indicator lights will be off even though
ndicator lights will be off even though
the power switch is turned on. The misting system will stop
the power switch is turned on. The misting system will stop
running automatically when the water supply to the pump
running automatically when the water supply to the pump
is stopped.
• Important: Never attempt to run the pump without
Never attempt to run the pump without
water. Please make sure the water supply is sufficient, then
water. Please make sure the water supply is sufficient, then
re-start the pump.
left of "Stop Spraying
t line, number of
R
M
OUTINE
AINTENANCE SCHEDULE
AINTENANCE SCHEDULE
Pump
Description
Action
Pump
Check Oil
Level
Filter
Clean
Every
Every 15 days
Nozzles
Clean
Pipes/Hoses
Flush
Every 15 days
Every 15 days
Oil
Oil Drain Plug
Oil Drain Plug
Typ
Volume
1. First 30~40 houres
First 30~40 houres
Time
2. Every 100~200 houres of use
Every 100~200 houres of use
GB
Frequence
Frequen
Before every
Before every
use
As necessary
As necessary
Oil Inlet Cover
Oil Window
WM Series
SAE 30~40
80 cc

Publicité

Table des Matières
loading

Ce manuel est également adapté pour: