Care and Cleaning of the Mixer
Motor Replacement
Electrical Shock Hazard.
w WARNING
Disconnect power before servicing. Replace
all parts before operating. Failure to do so can
result in death or electrical shock.
To replace the motor, follow the steps below,
or call an authorized service center.
1. Disconnect power
the mixer.
2. Loosen the
three screws
the top cover (the
screws will remain in
the cover). Lift off the
top cover.
3. Squeeze the
tabs on the sides
the connector plug
and pull the two plug
halves apart.
4. Remove the
agitator and then
lift the motor assembly
straight up and out of
the housing. Discard
the motor assembly
in an environmentally
acceptable manner
that complies with
federal, state, and
local waste
management
regulations.
NOTE: A Mylar insulating barrier with a top
tab and an opening is slipped over the lower
enclosure front screw boss. Make sure this
is in place and DO NOT remove.
8
5. Carefully lower the
new motor assembly
into the housing,
guiding the spindle
through the hole in the
housing. Align the keyed
portion on the rubber
support with the slot in
the top cover. Attach a
to
new agitator as described
in "Replacing the Agitator."
6. Plug the two halves of
in
the plug connector
together, ensuring that
all lead wire colors
match, and tuck the
connector into the back
of the housing. Make sure
of
that the side clips on the plug halves engage.
NOTE: The plug will only connect together in
one way.
7. Make sure that all wires are out of the way and
that they cannot come in contact with the motor.
Also ensure that the Mylar insulating barrier is
correctly positioned. Then lower the cover into
place, making sure that the upper tab and seal
of the back panel are in place below the lip of
the cover. Secure the cover with the screws.
8. Reconnect power to the mixer.