b. Fuse Replacement
Before fuse replacement, disconnect all test leads and/or ant connectors from any circuit
under test. To avoid damage to the instrument, replace the fuse only with specified ratings.
• Set the rotary switch to the OFF position.
• Disconnect all test leads and/or any connectors from the terminals.
• Open the battery compartment using an appropriate screwdriver.
• Remove the fuse by sliding it out of its bracket.
• Install a replacement fuse (F 500mA/250V, Ø 5 x 20mm).
• Close the battery compartment.
c. Battery Replacement
To avoid false readings, which could lead to possible electric shocks or personal injury,
replace the battery as soon as the battery indicator
disconnect all test leads and/or ant connectors from any circuit under test.
• Set the rotary switch to the OFF position.
• Disconnect all test leads and/or any connectors from the terminals.
• Open the battery compartment using an appropriate screwdriver.
• Remove the battery.
• Install a replacement battery (6F22).
• Close the battery compartment.

6. Technical Specifications

Accuracy is specified for one year after calibration at operating temperatures of 18°C ~ 28°C with a relative humidity
at 0% ~ 75%. Accuracy specifications take the form of ± (% of rdg + number of least significant digits).
Environmental Conditions
Pollution Degree
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Max. Voltage between Terminals and Earth 600VAC RMS or 600VDC
Fuse Protection
Sample Rate
Display
Over Range Indication
Polarity Indication
Auto Power-Off
Continuity Buzzer
Transistor Test
Diode Test
Low Battery Indication
Max. Display
Ranging Modes
Data Hold
Backlight
Power Supply
Dimensions
Weight
Accessories
DVM1400
1000V CAT. II and 600V CAT. III
2
< 2000m
0°C~40°C or 32°F~122°F (< 80% RH, < 10°C)
-10°C~50°C or 14°F~122°F (< 70% RH, battery removed)
0.1x / C° (< 18°C or > 28°C)
F500mA/250V, 5 x 20mm quick fuse
2x/sec for digital data
3
digits LCD with automatic indication of functions and symbols
5/6
yes ("OL")
"-" displayed automatically
yes, after 15 min
yes
no
yes, 1.0mA (open circuit voltage = 1.5VDC)
yes ( )
3,999 counts
manual or automatic
yes
yes
9V battery
180 x 85 x 45mm
± 280g (with battery)
1 x K-type thermocouple, 2 x test leads, 1 x 9V battery, manual
- 8 -