Installation Instructions; Flow Diagram - Hansgrohe Talis Care 32037000 Mode D'emploi / Instructions De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
(flow limiter) located behind the aerator can be
removed.
Technical Data
This mixer series-produced with EcoSmart
limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Hansgrohe mixers can be used together with hydrauli-
cally and thermically controlled continuous flow heaters
if the flow pressure is at least 0,15 MPa.
Fault
Insufficient water
Mixer stiff
Mixer dripping
Hot water temperature too low
4
English
®
(flow
®
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
Cause
- check valve hasn't moved back
- Cartridge defective, calcified
- Cartridge defective
- Hot water limiter incorrectly set
Assembly see page 31
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 33)
To adjust the hot water limiter on single lever
mixers, please see page 33. Using a hot
water limiter in connection with a continuous
flow water heater is not recommended.
Dimensions (see page 34)

Flow diagram

(see page 35)
with EcoSmart
without EcoSmart
Operation (see page 35)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Spare parts(see page 36)
Cleaning
see enclosed brochure.
Test certificate (see page 32)
Remedy
- Exchange check valves
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
®
®

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Talis s 32047000

Table des Matières