7 C
leanInG
and
WarnInG
• Only start cleaning and maintenance once the instructions in the "Switching off" section have been completed.
It is particularly important to always disconnect the electricity supply.
• To safeguard the safety of the high pressure cleaner, only use the original spare parts supplied by the Manufacturer
or those endorsed by him.
• The rubber pipes, the coupling and the high-pressure lances are important for safety: only use those endorsed by
the Manufacturer.
7.1 r
m
outIne
aIntenanCe
Follow the instructions in the "Switching off" section and abide by the recommendations in the table below.
INTERVAL FOR MAINTENANCE
Each time used
Weekly
Monthly
CautIon
• During use, the high pressure cleaner should not be too noisy and large amounts of water or oil should not drip
from underneath it.
In this event, a Skilled technician should test the appliance.
7.2 s
m
peCIal
aIntenanCe
WarnInG
• Only Skilled Technicians are authorised to carry out special maintenance.
Follow the instructions in the table below for special maintenance.
INTERVAL FOR MAINTENANCE
Every 50 hours
Every 100 hours
CautIon
• the data in the table are indications.
8 d
IsmantlInG
Only trained personnel are allowed to dismantle the high pressure cleaner in accordance with the current regulations
in the country where it is installed.
24
m
aIntenanCe
ACTION
• Check the supply cable, high-pressure pipe, couplings, cleaner gun, lance
pipe.
Should any of these parts appear to be damaged, do not use the high
pressure cleaner and contact a Skilled Technician.
• Clean the water inlet filter (26).
Usually, it is sufficient to pass the filter under running water or in a jet of
compressed air to clean it. In more difficult cases, use a lime scale remover or
replace the filter. Contact an authorised service centre for the purchase of a
new filter.
• Clean the nozzle.
For cleaning, it is generally enough to pass the supplied pin (19) inside the
nozzle hole. In case you do not obtain any appreciable result, apply to an
authorised service centre.
ACTION
Check the pump hydraulic circuit.
Check the pump fixing.
Replace the pump oil.
Check the pump suction/delivery valves.
Check the pump screws are tightened.
Check the pump adjustment valve.
Check the safety devices.