4.6 Transport
Always remove the batteries before shipping the tool.
5 Before use
5.1 Inserting the batteries 2
CAUTION
Do not use damaged batteries.
CAUTION
Always replace the complete set of batteries.
DANGER
Do not mix old and new batteries. Do not mix batteries
of different makes or types.
1.
Open the battery compartment.
2.
Remove the batteries from the packaging and insert
them in the tool.
NOTE Take care to observe correct polarity (see
symbols in battery compartment).
3.
Check to ensure that the battery compartment cover
is closed correctly.
5.2 Checking the tool
1.
Check to ensure that the sensor area is not damp. If
necessary, use a cloth to dry the sensor area.
6 Operation
6.1 Preparing the tool for use
CAUTION
Always drill at a safe distance from objects you have
detected.
1.
Before switching the tool on, check that it is not in
contact with anything and is clear of the working
surface or metal objects.
2.
For accurate results, allow the tool to acclimatize
itself to the ambient conditions before use if it has
previously been exposed to extreme temperature
fluctuations.
3.
Check how the tool is set before using it.
5.3 Switching the tool on / off
1.
Switch the tool on by pressing the on/off button.
After switching the tool on, the standard settings are
active.
2.
When the tool is already switched on, press the
on/off button: the tool switches itself off.
NOTE If the tool is not used or an error message
is displayed, it switches itself off automatically after
five minutes. The tool switches itself off when the
batteries are discharged.
5.4 Settings menu
1.
Switch the tool on.
2.
Press one of the arrow buttons (right or left) to go to
the settings menu.
3.
Press one of the arrow buttons to move through the
menu and make your selection.
4.
Press the scan and settings button to change the
settings.
5.
After making your selection, the tool will automatic-
ally return to the area display within 5 seconds and
is then ready for operation.
NOTE If no selection is made within 5 seconds, the
tool leaves the settings menu automatically.
2.
Switch the tool on by pressing the on/off button.
After carrying out a brief self-test, the tool begins to
calibrate itself automatically. The status LEDs light
green as soon as this has been completed.
While the tool is calibrating itself, hold it in the air at
least 30 cm (12 in) away from any metal objects and
away from the surface on which you are working.
3.
The first five times the tool is switched on, it runs
through an animated training program that demon-
strates how it should be used. This training program
can be switched off in the options in the settings
menus.
en
19