Calorex PROPAC 30 Manuel D'installation page 24

Masquer les pouces Voir aussi pour PROPAC 30:
Table des Matières

Publicité

PP90BMY TRIPHASEE (400V ~ 3 N 50Hz)
NEUTRE
VOYANT ALIMENTATION
BORNES 
D'ALIMENTATION 
HORLOGE
(N) 8
9 (L)
RELAIS (R2)
B
A
A2
A1
TEMPORISATION 4 
(30 SECS)
COMP 1 
VENTILETEUR 1 
CONTACTEUR
CONTACTEUR
A2
A1
(N/O) 74
73 (AUX)
VENTILATEUR 2 
COMP 2 
CONTACTEUR
CONTACTEUR
A2
A1
(N/O) 74
73 (AUX)
VOYANT 
DEGIVRAGE
VANNE D'INVERSION 
FRIGORIFIQUE 1
VANNE D'INVERSION 
FRIGORIFIQUE 2
2 (N)
TEMPORISATION 6 
(3 SEC)
3 (N/O)
A2
A1
4 (N/F)
RELAIS (R4)
(N/O) 18
15 (COM)
B
A
(N/F) 16
COM P 1 MCB AUX BLOCK
COMPRESSEUR 1 
TRIP / OFF = BREAK CONTA CT
CONTACTEUR
A2
A1
COMP 2 MCB AUX
COMPRESSEUR 2 
TRIP / OFF = BREAK CONTA CT
CONTACTEUR
A2
A1
DEMARRAGES 
ELECTROVANNE CIRCUIT 1
(SI INSTALLES)
(LIGNE ARRET LIQUIDE)
RECHAUFFEUR COMP 1
L1
COMP 
L2
1
L3
ELECTROVANNE CIRCUIT 2
(LIGNE ARRET LIQUIDE)
RECHAUFFEUR COMP 2
L1
COMP 
L2
2
L3
SCHEMA ELECTRIQUE
(N) 2
1 (L)
6 (COM)
(N/O) 4
(N/O) 4
(N/F) 1
(N/F) 5
(N/O) 6
9 (COM)
(N/F) 3
(N/O) 4
7 (COM)
(N/F) 1
1 (COM)
(COM) 8
5 (N/O) 
2 (N/F) 
B
A
(N/O) 18
15 (COM )
(N/F) 16
RELAIS (R3)
A 2
A1
TEMPORISATION 5 
(3 SEC)
15 (COM)
18 (N/O)
(COM) 9
6 (N/O) 
16 (N/F)
3 (N/F) 
A 2
A1
TEMPORISATION 2
(6 MINS)
18 (N/O)
15 (COM)
(COM) 7
4 (N/O) 
16 (N/F)
1 (N/F) 
A 2
A1
TEMPORISATION 3 
(7 MINS)
B
A
RELAIS (R1)
(N/O) 2
VENT 
(N/O) 4
1
(N/O) 6
(N/O) 2
VENT 
(N/O) 4
2
(N/O) 6
 
AMORTIS
(N/O) 84
83 (AUX)
(N/F) 22
21 (AUX)
(N/O) 2
1
(N/O) 4
3
(N/O) 6
5
CONTACTEUR
COMPRESSEUR 1
(N/F) 84
83 (AUX)
(N/F) 22
21 (AUX)
(N/O) 2
1
(N/O) 4
3
(N/O) 6
5
CONTACTEUR
COMPRESSEUR 2
page 23
DISJONCTEUR CIRCUIT ELECTRIQUE
MONITEUR DE 
TRIP / OFF = BREAK CONTACT
PHASES
L1
(COM) 11
L2
(N/O) 14
L3
BORNES D'INTER-
VERROUILAGE
7 (COM)
B
A
RELAIS (R5)
VOYANT DEFAUT
(N/O) 6
9 (COM)
(N/F) 3
(N/O) 4
7 (COM)
(N/F) 1
COMP 2 CONTACTEUR
(N/O) 54
COMP 1 CONTACTEUR
3 (N/O)
1 (COM )
(COM) 8
5 (N/O) 
(N/O) 54
4 (N/F)
2 (N/F) 
2 (N)
VALEURS DISJONCTEUR
CIRCUIT 
VENTILATEUR 
COMPRESSER 
1 ET 2
ELECTRIQUE
1 ET 2
2.5A
1.57A
19.8A
15 (COM)
18 (N/O)
16 (N/F)
A 2
A 1
TEMPORISATION 1 (12 
HEURES)
1
(N/F) 2
3
(N/F) 4
5
(N/F) 6
CONTACTEUR
DISJONCTEUR
VENTILATEUR 1
VENTILATEUR 1
TRIP / OFF = BREAK CONTACT
1
(N/F) 2
3
(N/F) 4
5
(N/F) 6
CONTACTEUR
DISJONCTEUR
VENTILATEUR 2
VENTILATEUR 2
TRIP / OFF = BREAK CONTACT
(N/F) 2
(N/F) 4
(N/F) 6
DISJONCTEUR
COMPRESSEUR 1
TRIP / OFF = BREAK CONTACT
(N/F) 2
(N/F) 4
(N/F) 6
DISJONCTEUR
COMPRESSEUR 2
TRIP / OFF = BREAK CONTACT
L1  L2  L3 
1
(N/F) 2
(N/F) 4
3
(N/F) 6
5
!
53 (AUX)
53 (AUX)
1
3
5
1
3
5
1
3
5
1
3
5
SD566252 ISSUE 46