SCHEMA ELECTRIQUE
PROPAC 45BM TRIPHASEE (400V ~ 3 N 50Hz)
DISJONCTEUR
CONTACTEUR
VENTILATEUR
5
6 (N/F)
5
3
4 (N/F)
3
1
2 (N/F)
1
A1
DISJONCTEUR
COMPRESSEUR
5
6 (N/F)
3
4 (N/F)
1
2 (N/F)
TEMPORISATION 6
MIN
11
(N/O)
RELAIS
(R2)
14
(COM)
(COM)
(N/F)
(N/O)
VOYANT
L
H
DEGIVRAGE
THERMOSTAT
DEGIVRAGE
C
(SE COUPE A H
(COM)
EN BASSE
TEMPERATURE)
BORNES D'ALIMENTATION
(N/O)
(N/F)
4
5
CONTACT 6 ET 4 EN BASSE
OUT 1
TEMPERATURE
6
(COM)
THERMOSTAT
COMMUTATEUR
VEILLE
[MARCHE] (I) (N/O) 2
1 (COM)
(N/O) 4
(VEILLE) (O)(N/F) 3
(COM)
7
(N/O)
CONTACT DEBIT
A
D'EAU INTERNE
RELAIS (R1)
DEMARRAGE
AMORTI
DISJONCTEUR
THERMIQUE
SI INSTALLE
DEMARREUR OU
CONTACTEUR DE
DEBIT
(EXTERNE)
PRESSOSTAT BP
(N/F) L
(SE COUPE A H EN
BASSE PRESSION)
PRESSOSTAT HP
(N/O) L
(SE COUPE A L EN
HAUTE PRESSION)
PROTECTION
THERMIQUE
VENTILATEUR
PROTECTION
MOTEUR
COMPRESSEUR
CONTACT DEFAUT
VENTILATEUR
CONTACT DEFAUT
COMPRESSEUR
DISJONCTEUR
CIRCUIT
ELECTRIQUE
5
6 (N/F)
L3
4 (N/F)
3
L2
1
2 (N/F)
L1
MONITEUR DE
L3 L2 L1
PHASES
6 (N/O)
4 (N/O)
VENTILATEUR
2 (N/O)
A2
CONTACTEUR
(W1)
5
6 (N/O)
(V1)
3
4 (N/O)
COMP
1
2 (N/O)
(U1)
A1
A2
21
22
COMP AUX
ELECTROVALVE
(NF)
(ARRET LIGNE LIQUIDE)
63
64
COMP AUX
(NO)
A2
A1
TEMPORISATION 1
12 HR
15
18
(N/O)
A1
A2
9
8
HORLOGE
10 11
VOYANT DEBIT D'EAU
1 (N/F)
B
H (N/O)
VOYANT
DEFAUT
C (COM)
H (N/F)
C (COM)
TK
(N/F)
TK
(N/F)
96
(N/F)
95
96
(N/F)
95
VOYANT ALIMENTATION
14 (N/O)
11 (COM)
NEUTRE
page 14
VALEUR DISJONCTEUR
CIRCUIT
COMPRESSEUR
VENTILATEUR
ELECTRIQUE
2.5A
23.8A
1.7A
SD566252 ISSUE 46