PoFF Automatic Cutoff
Under the menu item "PoFF" you can turn on/off the automatic cutoff
function.
- Confirm this menu item by pressing the "ENTER" (7) button.
- Use the "SET" (1) and "ALARM" (8) buttons to change the parame-
ters.
0 = Automatic cutoff is deactivated
1 = Automatic cutoff is activated
- Confirm your selection by pressing the "ENTER" (7) button to save the value or to exit the menu with-
out saving press the "ESC" (4) button.
t-CF - To adjust the temperature unit
Under the menu item "t-CF" the temperature unit can be adjusted
between °Celsius and the North American unit °Fahrenheit.
- Confirm this menu item by pressing the "ENTER" (7) button.
- Use the "SET" (1) and "ALARM" (8) buttons to change the parame-
ters.
0 = °Celsius
1 = °Fahrenheit
- Confirm your selection by pressing the "ENTER" (7) button to save the value or to exit the menu with-
out saving press the "ESC" (4) button.
AL - Alarm threshold for the CO
Under the menu item "AL" you can set the carbon dioxide alarm. If this
threshold value is reached or exceeded, there is a warning noise emit-
ted with each measurement. To set, proceed as follows:
- Confirm this menu item by pressing the "ENTER" (7) button.
- Use the "SET" (1) and "ALARM" (8) buttons to change the thresh-
old. This value can be adjusted across the whole measurement range of the device. If you hold down
the button the adjustment occurs in increments of 10 (fast setting).
- Confirm your selection by pressing the "ENTER" (7) button to save the value or to exit the menu with-
out saving press the "ESC" (4) button.
ALt - Set the height compensation
In order to obtain correct measurements, you need to set the opera-
tional altitude under the menu item "ALt". The setting is made as
metres above mean sea level (AMSL). To set, proceed as follows:
- Confirm this menu item by pressing the "ENTER" (7) button.
- Use the "SET" (1) and "ALARM" (8) buttons to change the altitude in metres. The operational altitude
can be adjusted between 0 and 9000 metres. If you hold down the button the adjustment occurs in
increments of 10 (fast setting).
- Confirm your selection by pressing the "ENTER" (7) button to save the value or to exit the menu with-
out saving press the "ESC" (4) button.
value
2
23