SEFRAM MW 3380 Notice D'utilisation page 25

Pince ampèremétrique 1000a ac
Masquer les pouces Voir aussi pour MW 3380:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

(3) AC Current
Function
A
(50~60Hz)
A
(61~400Hz)
Overload protection : 1000 Arms
* 1 AC Conversion Type and additional
accuracy is same as AC Voltage.
Position Error : ±1% of reading.
(4) Frequency : Hz
Range
20~400Hz
Overload protection : AC/DC 1000 Arms
Sensitivity : 3 Arms for ACA (A)
(>400Hz Unspecified)
(5) Peak Hold :
± (3% + 10dgt)
*>750Vpeak Unspecified.
*>800Apeak Unspecified.
The range is automatically switched to
the low resolution range at Peak Hold or
Min Max Hold.
Range
0~60.0A
60.1~400.0A
401~1000A
0~400.0A
401~1000A
Resolution
1Hz
25
Accuracy
±(1.9% + 7 dgt) *1
±(1.9% + 5 dgt)
±(2.5% + 7 dgt) *1
Accuracy
±(0.1% + 2 dgt)

Publicité

Table des Matières
loading