Operation
Note: Before any testing, make sure to clean the battery contacts.
1. Connect the Red Clamp (+) to the positive (+) terminal post on the battery. Connect
the Black Clamp (-) to the negative (-) terminal post on the battery.
2. Check the Battery Tester LED Window (See FIGURE 1) to determine effectiveness of
charge. If the Battery Tester does not register and no display is seen, double check that
the Clamps are connected to the proper terminal posts. Make certain a clean connection
has been made between the Clamps and terminal posts.
3. Flip the Load Switch until a solid and consistent measurement is indicated by the
Battery Tester. After ten seconds, read the meter with the Load Switch on. Do not test
more than three times in a five minute period. Allow one minute for cool down
between tests. Note: Do not activate the Load Switch for more than ten seconds. Note:
If a battery does not have the charge expected, have a qualified technician check the
specific gravity. There may be an electrical drain or charging system trouble. If charging
does not raise the specific gravity, you may have a defective battery. Analyzing test
results by color display: The Battery Tester will measure battery output/ charge in
two ways. The Condition Indicator (See FIGURE 1) will indicate a color telling you
the general condition of the battery.
Red = Bad, No Charge, or Completely Discharged
Yellow = Weak, Needs Recharging
Green = Good or Normal - Has Existing Charge
Analyzing test results by Voltage Reading: The color readout will indicate the battery
voltage.
Green = Greater than 11.2 V - Battery is fully charged;
Yellow = Between 9.5 and 11.2 V - Battery is undercharged;
Red = Less Than 9.5 V - Battery is uncharged and possibly damaged
4. If the battery is without significant charge, charge the battery according to the
manufacturer and make a new test. If the new test is without significant charge again,
then the battery is defective.
SW-Stahl GmbH
Leverkuser Straße 65
D-42897 Remscheid
Tel. +49 (0) 2191 / 46438-0
Fax +49 (0) 2191 / 46438-40
SW-Stahl GmbH
E-Mail: info@swstahl.de
An der Hasenjagd 3
D-42897 Remscheid
Tel. +49 (0) 2191 / 46438-0
Fax +49 (0) 2191 / 46438-40
E-Mail: info@swstahl.de
www.swstahl.de
www.swstahl.de

Publicité

loading

Produits Connexes pour SW-Stahl 34035L