Intake check - COMPRESSORS -
mechanical
The compressors are turned on/off as follows:
adjustment
SR2 = depending on the values indicated in setpoints of pressure switches "3"; "4"
SR3 = depending on the values indicated in setpoints of pressure switches "3"; "4"; "5"
Pressure switch setpoints
pressure
pressure
pressure
pressure
pressure
38
the compressors turn off, the low pressure rises
if the pressure exceeds the setpoint f pressure switch 2 for more than
30 min, the output relays of the controller are disabled.
the electrical-mechanical adjustment system is enabled
Refrigeration systems TN - R404A
compressor stop (dew) start (dew)
switch
2
/
3
I
4
II
5
III
Refrigeration systems TN - R134a
compressor stop (dew) start (dew)
switch
2
/
3
I
4
II
5
III
Refrigeration systems TN - R407F
compressor stop (dew) start (dew)
switch
2
/
3
I
4
II
5
III
Refrigeration systems BT - R404A
compressor stop (dew) start (dew)
switch
2
/
3
I
4
II
5
III
Refrigeration systems BT - R407F
compressor stop (dew) start (dew)
switch
2
/
3
I
4
II
5
III
Description
bar
3
4
0.8
1.5
1.0
1.7
1.2
1.9
bar
1.2
1.9
0
0.7
0.2
0.9
0.4
1.1
bar
2.5
3.5
0
0.7
0.2
0.8
0.3
1.0
bar
0.8
1.5
0.1
0.8
0.2
0.9
0.3
1
bar
0.3
1.0
0
0.7
0.1
0.8
0.2
1
diff.
stop start
°C
1
-12
-5
0.7
-33 -25
0.7
-30 -23
0.7
-28 -21
diff.
stop start
°C
0.7
-7
0
0.7
-26 -15
0.7
-23 -12
0.7
-19
-9
diff.
stop start
°C
1
-11
-4
0.7
-40 -28
0.7
-38 -26
0.7
-36 -24
diff.
stop start
°C
0.7
-33 -25
0.7
-44 -33
0.7
-42 -32
0.7
-40 -30
diff.
stop start
°C
0.7
-11 -24
0.7
-40 -28
0.7
-38 -26
0.7
-36 -24
05060162 00 02/02/2016