Advanced Operation Of The Transmitter; Trouble Shooting - SCS Sentinel intensive1A Safety kit Manuel D'installation Et D'utilisation

Pour portail à battants
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.8 Advanced Operation of the Transmitter

A
B
C
D
See the following description:
D
C
D
A
k
k
D
S
B
S
k

3. TROUBLE SHOOTING

Overheated Back-up Batteries
The gate doesn't move when pressing the
button of the transmitter
The gate only moves a little distance when
pressing the button of the transmitter.
The transmitting distance is too short
The gear motors run very slowly
The Flashing light does not work
The leaves shall be closed instead of opening
The leaves suddenly stop during moving
The leaves does not move or only move toward
one direction
The master gate closes to the end first and the
slave gate stops, the flashing light blinks fast for
five seconds.
The gear motors does not run and the relay is
noisy when operating the gate opening and
closing
Situation 1:
ASk: Transmitter button A for single leaf operation.
DkB: Transmitter button B for double leaves operation.
Situation 2:
BSk: Transmitter button B for single leaf operation.
DkA: Transmitter button A for double leaves operation.
Situation 3:
CSk: Transmitter button C for single leaf operation.
DkD: Transmitter button D for double leaves operation.
Situation 4:
DSk: Transmitter button D for single leaf operation.
k
DkC: Transmitter button C for double leaves operation.
Check the wiring connection of the batteries.
1. Check if LED3 or 4 is "ON".
2. Check if the voltage of the batteries is below 22V.
3. Check if LED1 is "ON".
4. Make sure all the wiring connections are firmly connected to the
terminals on the PCB.
5. Make sure the fuse is workable.
Make sure the wiring connection of the hall sensor is firm.
Make sure the connecting terminals of the
Antenna is firm.
Check the dip switch setting of the speed adjustment.
Check if the wiring connection of the flashing light is correct.
Change the polarity connection of the positive (+) with the negative (-)
of the gear motors.
1. Check if the "RESET" socket is activated.
2. Make sure the wiring connection of the gear motors is firm.
3. Make sure the hall sensor wiring connection is firm.
4. The GND terminal of the photocells on the PCB must be
short-circuited if no photocells installed.
5. Make sure the fuse is workable.
1. Check if the "RESET" socket is activated.
2. Make sure the wiring connection of the gear motors is firm.
3. Make sure the hall sensor wiring connection is firm.
4. The GND terminal of the photocells on the PCB must be
short-circuited if no photocells installed.
Cut off the AC input power and the output of the batteries. Release the
master gate and slave gate manually, then open the master to the end
and close the slave gate to the end by hand, then power the whole unit
by connecting the AC and battery terminals.
Check if the fuse is burned.
D
A
k
B
S
k
D
A
k
B
S
k
D
C
k
D
S
k
D
C
k
D
S
k
6

Publicité

Table des Matières
loading

Produits Connexes pour SCS Sentinel intensive1A Safety kit

Ce manuel est également adapté pour:

Intensive1a comfort kit

Table des Matières