2.1.4 Photocells Adjustment (Dip 7.Photo)
ON: When encountering any obstacles, the gates will stop during opening phase ; stop and reverse during closing phase.
OFF: The gate will keep moving when encountering any obstacles during closing and opening phases.
2.1.5 Flashing Light Adjustment (Dip 8.Light)
ON: The flashing light blinks for 3 seconds before the gate moves, and blinks simultaneously during the movement.
OFF: The flashing light blinks and the gate moves simultaneously.
2.2 SW2 Dip Switch Setting
2.2.1 Electric Latch Adjustment (Dip 5.Latch)
ON: The electric latch functions when dip switch is set to "ON".
OFF: The electric latch does not function when dip switch is set to "OFF".
2.2.2 Slowdown Speed Adjustment of The Gear Motors (Dip 6.Slow)
ON: The speed is 70% output of the full speed.
OFF: The speed is 50% output of the full speed.
2.2.3 Operation Speed Adjustment of The Gear Motors (Dip 7.Fast)
ON: The speed is 100% output of the full speed.
OFF: The speed is 80% output of the full speed.
2.2.4 Single and Dual Gate Operation Adjustment (Dip 8.Ds/Set)
ON: Dual Gates operation in system learning and normal operation.
OFF: Single Gate operation in system learning and normal operation.
2.3 LED Indication
LED1 System Learning: LED1 blinks once when single-gate learning is completed ;
LED2 RF : If the switch of the transmitter, key selector, or the push button is activated, LED2 will be on.
LED3 Photocells 1 : LED3 will be on when the first pair of the photocells are activated.
LED4 Photocells 2 : LED4 will be on when the second pair of the photocells are activated.
LED5 RF Indicator : LED5 will be on when RF signal is received.
Transformer
LED1 blinks twice when dual-gate learning is completed.
LED1
SYSlearn
LED2
RFLED
LED3
Ph01
LED4
Ph02
LED5
RFlearn
4