2). SETTING

2.1 SW1 Dip Switch Setting

2.1.1 Slowdown Adjustment (Dip 1.S/F Set)

ON: The gear motors do not slow down before the gates completely close or open.
OFF: The gear motors slow down before the gates completely close or open.
2.1.2 Over-current Adjustment (Dip 2.Over2 & Dip 3.Over1)
OVER1
Dip Switch 3 OFF
Dip Switch 3 ON
Dip Switch 3 OFF
Dip Switch 3 ON
2.1.3 Gate Auto-close Adjustment (Dip 4.Auto 3, Dip 5.Auto 2 & Dip 6.Auto 1)
Auto-close 1
Dip switch 6 OFF
Dip switch 6 ON
Dip switch 6 OFF
Dip switch 6 ON
Dip switch 6 OFF
Dip switch 6 ON
Dip switch 6 OFF
Dip switch 6 ON
Note: Auto-close mode activates when the gates move to the end position or stopped manually. If the transmitter,
push button, or the key selector is activated before the auto-close counting, the gate will close immediately.
3
Transformer
OVER2
Dip Switch 2 OFF
Dip Switch 2 OFF
Dip Switch 2 ON
Dip Switch 2 ON
Auto-close 2
Dip Switch 5 OFF
Dip Switch 5 OFF
Dip Switch 5 ON
Dip Switch 5 ON
Dip Switch 5 OFF
Dip Switch 5 OFF
Dip Switch 5 ON
Dip Switch 5 ON
Before powering on the control unit, the
following dip switch setting must be
decided by gate weight and installation
environment first. See Figure 2
NC: No Connection
Current (Amp)
2A
3A
4A
5A
Auto-close 3
Dip Switch 4 OFF
Dip Switch 4 OFF
Dip Switch 4 OFF
Dip Switch 4 OFF
Dip Switch 4 ON
Dip Switch 4 ON
Dip Switch 4 ON
Dip Switch 4 ON
Effect
No auto-close
3 sec.
10 sec.
20 sec.
40 sec.
60 sec.
120 sec.
300 sec.