2.4 Transmitter Memorizing and Erasing Process

(A) Transmitter Memorizing: Press and hold the S3 button on the PCB for 1 second and then the blue LED
indicator on the RF board will be "ON". Press A button for dual-gate installation ; press B button for
single-gate installation on the transmitter within 5 seconds. The transmitter learning is completed
when the blue indicator is "OFF".
(B) Transmitter Memory Erasing: Press and hold the S3 button on the PCB for three seconds.
(C) One radio receiver can be memorized with 200pcs of transmitters.

2.5 System Learning Process

Step1: Connect the master motor wires to M1 terminals and the slave motor wires to M2 terminals correctly. If only
one gate is installed, the motor wires have to be connected to M1 terminals.
Step2: Press and hold the S2 button on the PCB for 5 seconds. After LED1 blinks once per second, press the
button on the transmitter to choose dual-gate(A button) or single-gate(B button) system learning.
In system learning mode, the gates will proceed with the following procedures.
(A) Dual-Gate Mode: Slave Gate closes→Master Gate closes→Master Gate opens→Slave Gate opens→Slave
Gate closes→Master Gate closes.
(B) Single-Gate Mode: Master Gate closes→Master Gate opens→Master Gate closes.
The completion of system learning:
(A) For Dual-Gate installation: The system learning is completed when LED1 quickly blinks twice per second.
(B) For Single-Gate installation: The system learning is completed when LED1 quickly blinks once per second.
Notes:
(A) System learning fails and needs to be learned again when an unpredictable interruption occurs.
(B) Once the system learning is completed, there is no need to proceed with the learning process again when
there isa power failure.
(C) The slave gate opens 3 seconds after the master gate opens and the master gate closes 3 seconds after the
slave gate closes.

2.6 Gate Operation

Press the button "A" on the transmitter for dual-gate operation.
Press the button "B" on the transmitter for single-gate
operation in either single-gate or dual-gate installation.

2.7 Gate-moving Logic

(A) In gate-opening phase: The gates stop if the transmitter/push button/key selector is activated, and close when
the transmitter/push button/key selector is reactivated.
(B) In gate-closing phase: The gates stop if the transmitter/push button/key selector is activated, and open when
the transmitter/push button/key selector is reactivated.
(C) In gate-opening or gate-closing phase: For safety purpose, the gates stop if encountering obstacles.