Cooper Lighting Solutions Prevail Instructions D'installation page 3

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Tools required
#2 Phillips head screw driver, torque wrench.
N
ote:
Hardware and tools to mount wall plate to wall not
supplied.
Wall Mount (Figure 6.)
1.
Pull the supply wires out of junction box (not supplied)
and through the large hole in the center of the wall
plate.
2.
Secure attachment plate to the wall using four bolts
(not included).
3.
Follow instructions step 3 through 5 from pole mount
arm configuration.
Tools required
1/4" Allen wrench, #2 Phillips head screw driver, torque
wrench, drill and 7/16" drill bit.
Mast Arm Mount (Figure 7. and Figure 8.)
1.
Slip the mast arm mounting assembly over the mast
arm (making sure not to pinch any supply leads). Make
sure the mast arm is fully seated into the mast arm
adapter as it should bottom out against the adapter.
2.
Secure the mast arm adapter to the mast arm with
the (4) 3/8-16 x 3/8" set screws. Level the mast arm
adapter while tightening the set screws. Torque to 120
in-lbs.
3.
Drill a 7/16" hole through the mast arm and install the
3/8" bolt and nut. Use care when drilling this hole so as
not to damage any wires within the mast arm. Torque
to 120 in-lbs.
4.
Open fixture door by loosening the (4) Phillips head
screws (or thumb screws if supplied) on the door.
(Figure 8.)
5.
Remove wire grommet for fixture wires at the back of
the fixture. (Figure 8.)
6.
Fold fixtures wires and mast arm adapter wires out of
the way and slide fixture on to the mast arm adapter.
Tighten the three phillips head screws to 20 in-lbs. (2.3
N-M), and install the plastic plug over the center screw.
(Figure 7 .)
7 .
Make wire connections inside the fixture. Refer to wire
diagram for power connections. Connect the supply
wires to appropriate luminaire leads: (Figure 4.)
• Supply side ground wire to green luminaire lead.
• Supply side neutral wire to white luminaire lead.
• Supply side line voltage wire to black luminaire lead.
8.
Tuck wires into the fixture and install fixture door.
Tighten the (4) fixture door screws to 20 in-lbs. (or
tighten door thumb screws).
Installation Instructions – Prevail / USSL
Wall Plate
Figure 6.
Level Surface
3/8" Bolt
Figure 7.
Wire
Grommet
Figure 8.
COOPER LIGHTING SOLUTIONS
.44 dia
[11.20]
7 .12
[180.85]
Wireway
6x8 Plate Size
(Center Hole)
Mast Arm Pole
(2" Tenon Arm)
Set Screws (Torque to
120 in-lbs.)
Tighten to 20 in-lbs.
Open Fixture
Door
IB500002EN Installation instructions
8.00
[203.20]
3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ussl

Table des Matières