Technical Data

22
Electric generator
Art. No ................................................................................ 40657
 
Service connection ......................1 x 230 V ~ 50 Hz
Rated current ...................................................4 A / AC
 
Constant power ...........................1000 W / 1000 VA
Rated power..................................1200 W / 1200 VA
Power class .................................................................G1
Power factor ...............................................................1,0
Contents ..........................................................53,5 ccm
Engine type ................................1-cylinder 4-stroke
Motor output ......................................1,5 kW / 2,0 PS
Rated speed .................................... 4000-5200 min
 
tank capacity (Petrol) ........................................... 4,2 l
Consumption at half load ............................0,74 l/h
Oil amount .............................................................0,26 l
Weight .....................................................................12 kg
Dimensions L x B x H .............320 x 350 x 365 mm
Degree of protection ....................................IP 23 M
Noise and Vibration Information
Sound pressure level L
Uncertainty K = ...................................................... 1,07 dB (A)
Measured sound power level
....................................................................L
Guaranteed sound power level
..........................................................................L
Wear ear protectors!
Measured according to
control elements and how to use the appliance
properly. Abide by all the safety measures stated in
the service manual. Act responsibly toward third
parties.
The operator is responsible for accidents or risks to
third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
Persons over 16 years of age can only work on the
appliance. An exception includes youngsters trained
in order to reach knowledge under supervision of the
trainer during occupational education.
This appliance has not been designed to be used by
persons (including children) with reduced physical, sen-
sory or mental capabilities or with a lack of knowledge
or experience.
Children must be supervised in order not to play with
the machine.

Specified Conditions Of Use

This power unit has solely been designed for the
operation of electrical equipment with a maximum
power within the power unit performance data.
ISG 1200 ECO
...................................74,39 dB (A)
PA
94,39 dB (A)
1)
WA
WA
2000/14/EG
1)
Read and understand the operating
instructions before using the
appliance. Familiarise with the
Higher starting current of induction appliances must
be considered.
The unit has been designed for operation of common
effective and induction appliances such as light
chains, electric hand tools (drills, electric chain saws,
compressors).
Inverter
The rotor generates a 3-phase AC voltage of up to 500
Hertz depending on rotation speed. The inverter then
converts this to 50 Hertz AC. This achieves a very high
quality electrical waveform with minimal distortion
and optimum voltage stability. A clean sine wave and
minimal power fluctuations means it can also be used
to operate electrically controlled consumers.
-1
When connected to a stationary device such
as heating, electrical power, air conditioning
equipment or for the supply of mobile homes, it
is necessary to contact a professional electrician
and heating manufacturer as far as connection
and grounding is concerned.
Not observing general regulations in force and
instructions from this manual does not make the
manufacturer liable for damages.
Protective equipment „Protective separation with
potential balancing" is provided and integrated by
the producer.
Please note that our equipment has not been
designed for commercial, craft or industrial use. If the
95 dB (A)
1)
equipment is used in commercial, craft or industrial
operation or for similar activities, we cannot assume
any liability.
The machine may only be used in a technically
perfect condition and taking into account all safety
information.
Connection, installation and
operation
Caution: Before using the product it is essential
to check whether the appliance is suitable to be
operated with the unit. Specifications of the ap-
pliance must always match the details and safety
instructions of the unit.
Do not connect the appliance before the unit is run-
ning at full speed. Disconnect the appliance before
turning the unit off.
Never connect another appliance when there is
one being operated. This would inevitably lead to
fluctuations able to destroy electronically controlled
equipment.
The electric energy consumption is the critical point
of an induction appliance ehen starting. Electric
energy consumption can be 3-5 times higher than the
rated power that must necessarily be considered.

Residual risks

Even when the device is used properly and all safety

Publicité