POS. DESCRIPTION
1
Red plastic washer
2
White plastic washer
3
Blue plastic washer
4
Relief/non return valve
5
Hose clamp
6
Discharge pipe
7 A
Element gasket
from S/N 100.000
7 B
Element gasket
from S/N 200.000
8A
Electric element
1200W 220V
8B
Electric element
500W 220V
8C
Electric element
1200W 110V
8D
Electric element
600W 110V
9
Bi-Thermostat
10
Power supply cable
11A
B3 resistor cover 220V
11B
B3 resistor cover 110V
12
Nut
13
Ground cable terminal
14
Washer
15
Screw
16A
Tank mounting
B3 300
16B
Tank mounting
B3 360
16C
Tank mounting
B3 400
17A
Metal bracket
B3 300
17B
Metal bracket
B3 400
18
Screw
19
Washer
20
Nut
21
Cable clamp
22
Screw
BOILER B3 15-80 - REV006A
MAINTENANCE
WARNING: Quick
®
with a double thermostat with manual reset that
shuts down power supply in case of an excessive
water temperature.
If it happens, follow the instructions below:
• shut down power supply.
• Remove the protection cover (11) in order to reach
the thermostat (9).
• Push the reset button on the double thermostat (fig. 4).
• Replace on the protection cover (11).
• Switch on power supply.
WARNING: if the high temperature safety system
switches on repeatedly, call Quick
MAINTENANCE
We recommend checking the magnesium anode (A) every
12 months.
Replace the anode if its size has been reduced significantly.
This simple and preventive maintenance will ensure a long
life of the equipment.
During wintertime, when the water heater is not
F
in use it should be drained using the lever of the
valve (4). This is to avoid serious damage caused by
freezing.
The overpressure release device must be activated regularly
to remove calcium deposits and to ensure that it is not
blocked.
Periodically check the joints of the water pipe installation;
check the tightness of the securing screws and replace
them in case they are worn or corroded.
Also periodically check the electrical system working order.