Maintenance And Cleaning - Watts Dormont ReliaGuard Instructions D'installation Et D'utilisation

Raccord de gaz
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Recommendations for Maintenance and Cleaning
Recommendations for Maintenance and Cleaning Behind
Moveable Gas Appliances
WARNING
!
DO NOT USE the Standard Snap QD as the gas shutoff method when cleaning or servicing
the appliance .
Dormont recommends that the gas connector, accessories, and restraining
cable be checked during every cleaning . If there is any damage, contact a
professional for repair or replacement .
Disconnecting the Gas Line
1 .
Turn off the gas appliance .
2 .
Carefully pull the equipment away from the wall . Stop when the restraining cable is taut .
3 .
Turn off the gas supply at the manual shutoff valve located off the main manifold line . The
handle of the manual shutoff valve should be perpendicular to the valves .
4 .
Unplug any electrical cords in the area to be cleaned .
5 .
Disconnect the gas connector from the appliance using the Standard Snap QD .
6 .
Detach the restraining cable snap hook on the wall .
7 .
Carefully pull the gas appliance away from the wall .
8 .
Clean behind the equipment . Ensure that no grease, grime, cleaning solutions or other
chemical substances enter the Standard Snap QD, or the gas line .
WARNING
!
STRONG CLEANING SOLUTIONS OR CHEMICAL SUBSTANCES SHOULD NOT COME
IN CONTACT WITH THE GAS CONNECTOR OR ACCESSORIES. These may include
acids, solvents, fluxes with zinc chloride, or other chlorinated chemicals . If contact occurs,
rinse the gas connector and/or accessories with water and dry thoroughly with clean cloths .
If there are any signs of damage to the gas connector or accessories, turn off the gas supply
and have the gas line replaced by a professional immediately .
9 .
Carefully inspect the gas connector, fittings, restraining cable, and attachment points at
the wall and on the appliance . If there is any damage, contact a professional for repair or
replacement .
Reconnecting the Gas Line
1 .
Reconnect the Standard Snap QD .
2 .
Reattach the restraining cable to the wall .
3 .
Plug in any electrical cords in the area that were previously unplugged .
4 .
Turn the handle on the manual gas shutoff valve to the "On" position . The handle of the
manual shutoff valve should be parallel to the valves .
5 .
Carefully push the appliance back toward the wall .
WARNING
!
Make sure that the casters do not roll over the connector and that the connector is not twist-
ed, kinked, torqued, crushed, or otherwise damaged .
6 .
If required, re-light the pilot light and turn on the equipment .
12

Publicité

Table des Matières
loading

Table des Matières