Watts Dormont ReliaGuard Instructions D'installation Et D'utilisation page 11

Raccord de gaz
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ReliaGuard and Accessory Devices Installation Steps
NOTICE
For all options make sure all connections have been tightened with wrenches and a leak test
is performed .
NOTICE
Refer to the additional install instructions and warnings provided with the Dormont Standard
Snap QD, and Restraining Cable products .
Option 1: Quick Disconnect (QD) Installed at Appliance Side with
Manual Shutoff Valve Installed at Gas Supply Manifold Side plus
SwivelGuard swivels
1 . Connect the pipe nipple to the gas supply manifold tee fitting .
2 . Connect the pipe elbow to the pipe nipple .
3 . Connect the manual shutoff valve to the pipe elbow .
4 . Connect the ReliaGuard end fitting to the manual shutoff valve . If installing SwivelGuard
connect the female end to the ReliaGuard end fitting and the male end to the manual
shutoff valve .
5 . Connect the QD female coupler to the other ReliaGuard end fitting . If installing SwivelGuard
connect the female end to the ReliaGuard end fitting and the male end to the QD female
coupler .
6 . Connect the pipe elbow to the gas appliance inlet fitting .
7 . Connect the QD male nipple to the pipe elbow .
8 . Connect the QD female coupler to the QD male nipple .
9 . Connect the restraining cable to the back of the appliance and the wall .
Option 2: Quick Disconnect (QD) and Manual Shutoff Valve
Installed at Gas Supply Manifold Side plus SwivelGuard swivels
1 . Connect the pipe elbow to the gas appliance inlet fitting .
2 . Connect the ReliaGuard end fitting to the pipe elbow . If installing SwivelGuard connect the
female end to the ReliaGuard end fitting and the male end to the pipe elbow .
3 . Connect the pipe nipple to the gas supply manifold tee fitting .
4 . Connect the pipe elbow to the pipe nipple .
5 . Connect the manual shutoff valve to the pipe elbow .
6 . Connect the pipe nipple to the manual shutoff valve .
6 . Connect the QD female coupler to the pipe nipple .
7 . Connect the QD male nipple to the other ReliaGuard end fitting . If installing SwivelGuard con-
nect the female end to the ReliaGuard end fitting and the male end to the QD male nipple .
8 . Connect the QD female coupler to the QD male nipple .
9 . Connect the restraining cable to the back of the appliance and the wall .