Configure and calibrate the other sensors
Following is the procedure to configure and calibrate Trim, Fresh water level, Waste water level and
Rudder angle sensors:
1. Press the MENU button and select SENSOR
CONFIG.
2. Use Engine 1 connector or Engine 2
connector to select the connector to which the
sensor is connected.
3. Select the input connected to the sensor (i.e.
Resistive pin 8): "Off" appears to indicate that
no sensor is linked to the input or was disabled.
4. Select the sensor type: Show value as and
Calibration parameters appear.
5. Select Show value as, then select the ID to be
assigned to the engine/tank connected to the
sensor.
6. Select Calibration , then select Do 3 point
cal: calibration instructions and the ohm value
read in real-time by the sensor [A] appear. For
tanks, they must be drained, wait until the
value read stabilizes and press the ENTER
button.
7. Proceed with all calibration points following the
wizard.
8. Hold down the MENU button to return to the
data pages.
Delete a calibration
1. Press the MENU button and select SENSOR CONFIG.
2. Select the connector and input linked to the sensor: the sensor type and calibration status appear.
3. Select the calibration status and select Delete cal: any manual calibrations are deleted and factory
settings restored.
4. Hold down the MENU button to return to the data pages.
7" TFT display | Operating instruction v. 1.0 | © 2018 Continental Automotive Switzerland AG
Sensor configuration
69