Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• The diverter (type HC) installed in the bath mixer is
designed as an anti-retraction device. For this reason,
the lower edge of the diverter must be at least 25 mm
above the highest possible dirty water level.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Centre distance:
Connections G 1/2:
Safety against backflow
The product is exclusively designed for drinking water!
Fault
Insufficient water
Instantaneous heater didn't work
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
150 ± 12 mm
cold right - hot left
Cause
- check valve hasn't moved back
- Shower filter seal dirty
- Flow limiter in handshower isn't
removed
- Shower filter seal dirty
- check valve hasn't moved back
Assembly see page 32
Symbol description
Do not use silicone containing acetic acid!
Dimensions (see page 31)

Flow diagram

(see page 31)
Shower outlet 1B
Tub outlet
Maintenance (see page 36)
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
Operation (see page 34)
Spare parts (see page 35)
Cleaning
see enclosed brochure
Test certificate (see page 36)
Remedy
- Exchange check valves
- Clean filter seal between shower
and hose
- Remove flow limiter
- Clean filter seal between shower
and hose
- Exchange check valves