ON- -BOARD BATTERY CHARGER FAULT CODES
FAULT CODE
Yellow Light Flashing
Red Light Flashing
14
FIG. 31
FIG. 32
FAULT
Loose charger cable connection
Loose or damaged battery cable
Unsuitable battery
Output short circuit -- damaged output cable
Internal short circuit -- blown output fuse
Safety timer exceeded maximum charging
time
6. Once the charging cycle begins, the indicator lights
will progress from red, yellow to green (Figure 33).
When the green indicator light comes on, the
charging cycle is done. Unplug the charger cord.
If the charger detects a problem, the charger will
display an fault code (See ON--BOARD BATTERY
CHARGER FAULT CODES).
SOLUTION
Check charger cable connection
Check battery cable connections
Replace with proper battery
Contact Service Center
Replace battery charger
Repeat charging cycle. If error repeats,
replace batteries