This filter cannot be washed or regenerated. It must be replaced when the C appears on the
display or at least once every 4 months. The filter saturation alarm has to be activated already
before.
Activation of the alarm signal
• In the recycling version hoods the filter saturation alarm must be activated during the
instal-lation or later.
• Switch off the hood and the lights.
• Press the E-key for about 5 seconds until an animation appears on the display
• Within 5 seconds press the D-key to activate/deactivate charcoal filter saturation alarm.
C-symbol lit - charcoal filter saturation alarm ACTIVATED.
C-symbol unlit - charcoal filter saturation alarm DEACTIVATED.

REPLACINg ThE ChARCOAL FILTER

Alarm reset
• Press the g-key for at least 2 seconds.
Replacing the filter
• If close, open the upper panel (see Part USE).
• Remove the metal filters.
• Remove the saturated charcoal filter as indi-
cated (A).
• Fit the new filters as indicated (B).
• Put the metal grease filters in their seats.

LIghT REPLACEMENT

20 W halogen light.
• Extract the lamp from the lamp holder by pull-
ing gently.
• Replace with another of the same type,
making sure that the two pins are properly
inserted in the lamp holder socket holes.
Charcoal filter (recycling version)
Lighting
MAINTENANCE