Waterous PB18 Série Instructions D'utilisation page 3

Table des Matières

Publicité

Page 3 sur 19
Scalding Water Hazard. May result in serious burns.
When operating the pump, be sure to open at least one discharge valve slightly to prevent the pump from
overheating. If the pump runs for a few minutes completely closed, it may heat the water enough to scald
someone when the valve is opened. Overheating can damage the packing, seals and other pump parts. If the
apparatus builder has installed a by-pass system or other provision designed to prevent overheating, opening
a discharge valve may be unnecessary.
Suction and high pressure hazard.
May cause injuries to the hands, fingers or severe cuts or abrasions to the skin.
Never insert hands or fingers into the intake or discharge openings while engine is running. Never spray high pressure water
at a person or animal.
Risque de surchauffe de la pompe.
Peut endommager la pompe
Ne pas faire fonctionner la pompe à sec de façon prolongée pour éviter à la pompe de surchauffer.
REMARQUES IMPORTANTES :
1. Plage de températures opérationnelles ambiantes : -18° F à 118° F (-28° C à 48° C)
2. Niveau sonore maximum : 94 dBa à 1,5 mètre
3. Les pompes portables de la série PB18 sont conçues pour être portées par au moins deux personnes.