Calculating Vent System Length - KitchenAid KVUB606DSS Instructions D'installation Et Guide D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Calculating Vent System Length

To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
6" (15.2 cm) Round Vent System
Vent Piece
45° elbow
90° elbow
6" (15.2 cm) wall cap
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm)
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
to 6" (15.2 cm) 90° elbow
Example vent system
90˚ elbow
2 ft (0.6 m)
Maximum Recommended Length
1 - 90° elbow
1 - wall cap
8 ft (2.4 m) straight
Length of 7" (17.8 cm) system
3¹⁄₄" x 10" (8.3 cm x 25.4 cm) Vent System
Vent Piece
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
90° elbow
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
flat elbow
3¹⁄₄" x 10" (8.3 cm x 25.4 cm)
wall cap
6
Round
2.5 ft
(0.8 m)
5.0 ft
(1.5 m)
0.0 ft
(0.0 m)
4.5 ft
(1.4 m)
5.0 ft
(1.5 m)
Wall cap
6 ft (1.8 m)
= 50 ft (15.2 m)
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
= 13.0 ft (3.9 m)
5.0 ft
(1.5 m)
12.0 ft
(3.7 m)
0.0 ft
(0.0 m)
Example vent system
¹⁄₄
3
" x 10"
(8.3 x 25.4 cm)
elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Maximum Recommended Length
1 - 90° elbow
8 ft (2.4 m) straight
1 - wall cap
Length of system
Non-Vented (recirculating) Installations Through the Soffit/
Cabinet
If it is not possible to vent cooking fumes and vapors to the
outside, the range hood can be used in the non-vented
(recirculating) version, using a recirculation kit. The recirculation
kit Part Number is W10490330. See "Assistance or Service"
section to order.
For non-vented (recirculating) installations only, the range hood
can be vented indoors through the top of the cabinet or soffit.
Through Cabinet
A
G
B
D
F
E
A. Ceiling
B. Vent cover
C. Soffit
" (15.2 cm) vent
D. 6
E. Range hood
NOTE: 12" (30.5 cm) high cabinets without a soffit may allow the
6" (15.2 cm) vent and vent cover to be seen.
Wall cap
= 35 ft (10.7 m)
= 5.0 ft (1.5 m)
= 8.0 ft (2.4 m)
= 0.0 ft (0.0 m)
= 13.0 ft (3.9 m)
Through Soffit
G
F
H
F. Cabinet
G. Wall
H. 17" (43.2 cm) min. vent cover
height
A
B
C
D
E

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Kvub600dss

Table des Matières