EHEIM compactON 2100 Mode D'emploi page 20

Masquer les pouces Voir aussi pour compactON 2100:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 24
English
4. Commissioning
Connecting the hose
1. Use a saw to shorten the connecting piece to the diameter of your hose (⌦A).
2. Screw the connecting piece onto the pump.
3. Connect your hose to the connecting piece.
Installing suction devices
1. Screw the suction devices into the openings of the body of the engine (⌦B).
Hint: Moisten the suction devices with water for easier installation.
Installing the pump cover for external use
The pump can be used inside and outside of the aquarium. Among the benefits of the
pump cover c for external use is that it allows the connection of an inlet hose.
1. Loosen and remove the two lateral fastening screws a (⌦C).
2. Pull the pump cover b with integrated power controller out of the engine body from
the front.
3. Push the pump cover c into the engine body (⌦D).
4. Tighten the pump cover with the locking ring (⌦E).
▶ Make sure that the lugs on the pump cover engage in the recesses in the motor
body.
▶ Make sure that the impeller is installed complete with the two axle grommetsd (⌦I).
▶ Make sure that the locking ring engages.
5. Screw the intake nozzle into the pump cover.
6. Connect your hose to the intake nozzle.
7. You can re-install the pump cover with integrated power controller in reverse order.
5. Operation
CAUTION! Material damage.
The pump must not run dry.
20