user operation guidelines
Controller
i set
Initial Start Up
Your new Foster Cabinet will be delivered ready to run. Plug into the mains supply and the
6
unit will operate in the following way.
Start Up & Self Test: The indication is only displayed during the first three seconds
following the mains electrical power being applied to the unit. During this period the
controller performs a self-check.
Once the self-check has been completed
Operator Instructions
7
1. To Start the Unit
Press and hold
for three seconds. The unit will start and the air temperature will be displayed.
2. To Check Storage Temperature Set Point
i set
Check set point by pressing the button
Exit from set up occurs after 10 seconds if no button is pressed.
3. Manual Defrost
To initiate a manual defrost press and hold
ee
F
On completion of the defrost
will be displayed until the cabinet temperature is achieved and then it will revert to
displaying the normal cabinet temperature.
4. Set Unit to Standby.
OFF
Press
display shows
(standby indication)
Standby Indication
This indication is displayed while the unit is not operating but with mains power applied to the unit. This mode may be used for
internal cleaning regimes and short periods when the unit is not required.
For extended periods of inactivity the mains supply should be isolated.
Alarms and Warnings
8
Door Open Alarm (Only applies to cabinets fitted with door switches.)
O
Will be displayed.
The alarm will sound but can be silenced by pressing.
The display will continue to display the alarm message until cancelled by shutting the door.
If the alarm cannot be cancelled by doing this call your Foster Authorised Service Company.
High Pressure Alarm. (Only applies to machines fitted with a condenser probe).
HP
Will be displayed.
This alarm relates to the condenser which must be checked and cleaned at regular intervals the frequency being
determined by site conditions. (See 'Condenser Clean' instruction).
The alarm will sound but can be silenced by pressing any of the buttons and the unit will continue to operate, however
it will return after the pre-set designated period. The unit returning to normal operating temperature will automatically
cancel the alarm. If this does not occur after 4 hours check that the condenser is clean and clear of any obstruction or
call your Foster Authorised Service Company.
High temperature alarm
HI
Will be displayed.
The alarm will sound but can be silenced by pressing any of the buttons, however it will return after the pre-set
designated period. If the unit returns to normal operating temperature the alarm etc. will be cancelled automatically.
If this does not occur after 4 hours call your Foster Authorised Service Company.
GB
OFF
will be displayed.
EF
will be displayed release.
english
-
3