1. Install transition on top of hood (if removed for shipping) with
2 - 3.5 x 9.5 mm sheet metal screws.
A
B
A. Vent transition
B. 3.5 x 9.5 mm screw
2. Position the 4 vertical supports (A) with notches at the
bottom, and then attach to the range hood using 16 - 4.2 x 8
mm screws.
3. Attach the horizontal support (B) using 8 - 4.2 x 8 mm screws.
A
A. Vertical supports
B. Horizontal support
4. Attach a second set of vertical supports (A), and then set the
vertical height (B). See "Installation Dimensions" in the
"Location Requirements" section to help determine the
desired dimension for vertical height (B). Secure with
®
16 - 4.2 x 8 mm T20
screws.
A
A. Vertical supports
B. Vertical height
5. Using 2 or more people, lift the range hood assembly and
attach it by snapping the vertical supports to the spring clips
in the upper horizontal support bracket that is mounted to the
ceiling.
8
Assemble and Install Range Hood
B
A
A
B
NOTE: The range hood assembly must be held in place while
installing the screws in the next step.
6. Install 16 - 4.2 x 8 mm screws, and then tighten to secure.
A
A. Mounting screws
Connect Vent System
1. Install vent system.
2. Push duct over the exhaust outlet. Seal all connections with
vent clamps.
3. Use caulk to seal all openings.
Non-Vented (Recirculating) Installation
1. Attach the air deflector to the upper horizontal support using
4 mounting screws.
B
A
A. Deflector
B. Mounting screws
2. Measure the length of 6" (15.2 cm) duct needed to connect
the transition to the deflector.
NOTE: Vent should fit up inside the deflector 1" (2.5 cm)
minimum.
3. Install vent between the transition and the deflector.
NOTE: To make vent installation easier, temporarily remove
the deflector from the chimney support bracket, and then
replace after vent section is in place.
4. Seal all connections with vent clamps.
B