Raccordement - Datalogic SG BODY COMPACT MUTING Série Guide Rapide

Table des Matières

Publicité

RÉCEPTEUR (RX)
OSSD1 PNP
OSSD2 PNP
6
7
0 V
1
+24 Vcc
MUTING2
2
3
0 V
M12 8 pôles :
1 = blanc
= TEST/START
2 = brun
= +24 Vcc
3 = vert
= OVERRIDE 1
4 = jaune
= EDM
5 = gris
= OSSD1
6 = rose
= OSSD2
7 = bleu
= 0 V
8 = rouge
= OVERRIDE 2
M12 5 pôles :
1 = brun
= +24 Vcc
2 = blanc
= MUTING2
3 = bleu
= 0 V
4 = noir
= MUTING1
5 = gris
= NON UTILISÉ

RACCORDEMENT

EDM
5
4
contact extérieu r N.F .
OVR1
3
contact e xtérieur N.O.
2
+24 Vcc
8
OVR2
contact e xtérieur N.O.
+24 Vcc
1
NON UTILISÉ
4
MUTING1
+24 Vcc
NON UTILISÉ
+24 Vcc
0 V
NON UTILISÉ
M12 4 pôles :
1 = brun
2 = blanc = NON UTILISÉ
3 = bleu
4 = noir
M12 5 pôles :
1 = brun
2 = blanc = NON UTILISÉ
3 = bleu
4 = noir
5 = gris
2
ÉMETTEUR (TX)
1
2
4
3
0 V
1
2
4
3
0 V
= +24 Vcc
= 0 V
= NON UTILISÉ
= +24 Vcc
= 0 V
= NON UTILISÉ
= NON UTILISÉ
+24 Vcc
NON UTILISÉ
+24 Vcc
NON UTILISÉ
NON UTILISÉ

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sg2 body compact mutingSg4 body compact mutingSg4-s-pp-x série

Table des Matières