Symptom
Problem
DraftMax Ultra only
Fan does not
Downdraft
start running.
table does not
function.
Irregular filter
One of the
cleaning.
filter
cartridges is
not being
cleaned.
Poor extraction
No filter
capacity.
cleaning.
Button
No filter
MANUAL
does
cleaning.
CLEANING
not react.
Buzzer emits
Filter cartidges
polluted.
an interrupted
sound (2
seconds on - 2
seconds off).
Buzzer emits
Filter cleaning
system does
an interrupted
not function.
sound (2
seconds on - 5
seconds off).
Buzzer keeps
Operation hour
emitting
counter does
continuous
not start at 0
sound after
after filter
filter
replacement.
replacement.
8
SPARE PARTS
The following spare parts are available for the downdraft table
(refer to exploded view Fig. III on page 101):
Ref.
Article no.
Description
A
0040900020
Pressure regulator
B
0040000040
Pre spark arresters (set of 2)
C
0040100060
Spark arresters (set of 2)
D
0040000020
DuraFilter FCC 52
E
0040900270
Safety switch
F
0040900050
Fan wheel (60Hz/3400 rpm)
0040900060
Fan wheel (50Hz/2800 rpm)
G
0000101348
Motor 2,2 kW; 230-400V/3ph/50Hz
0040900080
Motor 3 kW (4 HP); 208-240V/480V/3ph/60Hz
(USA)
0040900090
Motor 3 kW (4 HP); 600V/3ph/60Hz (Canada)
0507060400/151013/G DraftMax Basic | DraftMax Advance | DraftMax Ultra
Possible cause Solution
PLC has not
Wait 10 seconds
started up.
after turning on the
main switch and try
it again.
No compressed
Connect/repair
air available.
compressed air
supply.
Automatic start/
Connect cable of
stop (movement
automatic start/stop
sensor or
(refer to Fig. 2.3A).
welding cable
sensor) not
connected.
Sensor of
Replace sensor.
movement
sensor defective.
Welding cable
Connect clamp of
sensor not
welding cable sensor
mass
connected.
to
cable of
welding machine.
One of the
Replace both
membrane
membrane valves.
valves defective.
Membrane
Replace both
valve(s)
membrane valves.
defective.
PLC defective.
Replace PLC.
Button
Replace button
RESET
/
/
ALARM
MANUAL
ALARM
MANUAL
.
CLEANING
CLEANING
defective.
Button pushed
Push button during
too short.
at least 5 seconds.
Less than 20
Try again later.
operation hours
Probably it is not
after downdraft
necessary to clean
table came into
the filter cartridges.
use.
Less than 20
Try again later.
operation hours
Probably it is not
after filter
necessary to clean
replacement/
the filter cartridges.
reset.
Pressure over
Push button
the filter
/
ALARM
MANUAL
cartridges has
to
CLEANING
reached 1500
suppress buzzer.
Pa.
Subsequently push
the same button
during 5 seconds to
activate the filter
cleaning system.
No compressed
Connect/repair
air available.
compressed air
supply.
PLC has not been
Reset PLC (refer to
reset.
section 5.4).
Ref.
Article no.
H
0040900210
0000102289
I
0040900200
0040900220
J
0040900240
K
0040900250
L
0040900230
M
0040900300
N
0040900170
O
0040900110
P
0040900170
Q
0040900100
R
0040900130
S
0040900120
T
0040900160
U
0040900040
V
0040900180
W
0046030010
X
0040900280
Y
0040900010
9
ELECTRICAL DIAGRAM
Refer to the separately supplied electrical diagram.
RESET
10
DISPOSAL
After life of the product, dispose it of in accordance with state or
local regulations.
EC DECLARATION
EC declaration of conformity for machinery
RESET
We, Plymovent Manufacturing B.V., Wezelkoog 11, 1822 BL
Alkmaar, the Netherlands, herewith declare, on our own
responsibility, that the products:
- DraftMax Basic
- DraftMax Advance
- DraftMax Ultra
which this declaration refers to, are in accordance with the
conditions of the following Directives:
- Machine Directive 2006/42 EC
- EMC2004/108 EC
- LVD 2006/95 EC
- ErP Directive 2009/125 EC
Alkmaar, the Netherlands, November 1, 2013
.
M.S.J. Ligthart
Product Manager
Description
Relay 100 C-16K (60Hz)
Relay MC2A
Thermal relay 4-6,3 A
Thermal relay 3,2-16 A
Fuse 1A (CC MR1)
Fuse 500 mA
Transformer UL 65 VA
PLC (Logo! 24RC)
Fuse 24V circuit 2A slow blow
Pressure difference switch 6-50 mBar
Fuse 24V circuit 2A slow blow
PC board control
Push button green incl. light
Push button black
Buzzer
Pressure gauge
Main switch
Safety valve compressed air tank
Compressed air presence switch
Pressure relief valve
EN - 15