FILTER CLEANING
DECOLMATAGE DES FILTRES
PULIZIA DEL FILTRO
LIMPIEZA DE LOS FILTROS
B
548149
A
Fig. 5.2: Control panel DraftMax Advance
5.2.2 Operation
Fig. 5.2
•
Turn on the main switch (A).
•
Push the
/
button (C) to switch on the fan.
ON
OFF
•
Start welding/grinding.
•
After finishing welding/grinding, push the
to switch off the fan.
5.2.3 Filter cleaning
Fig. 5.2
•
During use, regularly check the Pressure gauge (B). When
the pressure reaches 1200 Pa, the filter cartridges need to
be cleaned.
Filter cleaning procedure:
The filter cleaning procedure takes place online.
•
Make sure the downdraft table is switched on.
•
Press button
FILTER CLEANING
filter cleaning system.
The filter cleaning procedure takes 2 minutes, during which each
filter cartridge is cleaned by 7 compressed air shots.
ATTENTION!
To secure optimum filter efficiency, do not activate the
filter cleaning system within the first 20 hours of
operation or within 20 hours after filter replacement.
•
Check the pressure on the pressure gauge (B). If the
pressure still exceeds 1200 Pa, repeat the filter cleaning
procedure (max. 5 times).
5.2.4 Filter replacement
If the filter cleaning system is unable to get the pressure below
1200 Pa after 5 attempts, the filter cartridges are probably
saturated and need to be replaced.
Fig. 5.2
•
Push the
/
button (C) to switch off the fan.
ON
OFF
•
Refer to section 5.4 for the filter replacement procedure.
5.3
DraftMax Ultra
5.3.1 Control panel
The control panel is fitted with the following controls and
operators:
0507060400/151013/G DraftMax Basic | DraftMax Advance | DraftMax Ultra
ON / OFF
FILTERREINIGING
FILTERREINIGUNG
/
button (C)
ON
OFF
(D) for 5 seconds to activate the
Fig. 5.3
A
Main switch
B
Pressur gauge
C
/
button
ON
OFF
C
D Button
RESET ALARM
E
Buzzer
D
E
B
548123
A
Fig. 5.3: Control panel DraftMax Ultra
5.3.2 Operation
Fig. 5.3
•
Turn on the main switch (A).
•
Wait 10 seconds so PLC can start up.
Without movement
sensor and welding
cable sensor:
•
Push the
/
ON
OFF
button (C) to
switch on the
fan.
•
Start welding/
grinding.
•
After finishing
welding/
grinding, push
the
/
ON
OFF
button (C) to
switch off the
fan.
5.3.3 Automatic filter cleaning
Each time the downdraft table is switched off, the filter
cartridges are automatically cleaned by a full cleaning cycle.
This procedure takes max. 7 minutes, during which each filter
cartridge is cleaned by max. 10 compressed air shots.
To secure optimum filter efficiency the filter cleaning
system will not be activated during the first 20 hours
of operation or within 20 hours after filter
replacement.
5.3.4 Manual filter cleaning
If desired, the filter cleaning system can be activated manually
(online cleaning only).
Fig. 5.3
•
Push the
/
ON
OFF
/
MANUAL CLEANING
ON / OFF
RESET ALARM / MANUAL CLEANING
RESET ALARM / HANDMATIGE REINIGING
ALARMRESET / MANUELLES REINIGEN
REENCLENCHEMENT ALARME / DECOLMATAGE MANUEL
RIPRISTINO ALLARME / PULIZIA MANUALE
APAGAR ALARMA / LIMPIEZA MANUAL
With movement
With welding cable
sensor:
sensor:
(for welding only):
•
Start welding/
•
grinding.
The fan will start
and stop
automatically.
•
The fan will start
and stop
automatically.
button (C) to switch on the fan.
C
D
E
Apply the clamp
of the welding
cable sensor to
the mass cable
of the welding
machine.
Start welding.
EN - 12