Maintenance • Mantenimiento
Entretien • Manutenção
1
*1 EWC 150202 =
*2 EWC 13 08 02 =
20
2
6
5
European waste disposal key
Código de residuos europeo
Code européen de déchet
Europese afvalsleutel
European waste disposal key
Código de residuos europeo
Code européen de déchet
Europese afvalsleutel
Procedure
• Place new OEKOSORB filter set near
the unit. Keep the PE packaging of the
new set for putting in the old filters.
• Shut off condensate inlet
• Open the QWIK-PURE cover, and
remove the filter mat and the inlet.
• Slowly remove the used pre-filter and
3
the main filter from the container and
let them drain.
• Put the drained filter set into the PE
4
packaging and ensure correct disposal
*1.
• Insert a new filter set into the filter
receptacle of the container.
• Insert the filter mat into the pressure
relief chamber and mount th cap.
• Open condensate inlet.
General cleaning of QWIK-PURE
(recommended every 12 months)
- Remove off the cap and remove the
filter mat
- Remove the OEKOSORB filter
- Pump out the container
- Clean the container
- Ensure correct disposal of the liquid.
*2
- Replace the OEKOSORb-Filter and
the filter mat
Note:
Do not add any cleaning agents (sur-
factants or flammable cleaners)! They
impair the filter efficiency.
After cleaning, fill the QWIK-PURE unit
with fresh water.
(see 'Putting into operation', page 16).
Spent filters must be properly disposed
of.
After maintenance work
• Open condensate inlet.
(if necessary switch off compressor).
english
QWIK-PURE 25, 50