The unit is equipped with a superhetherodyne AM receiver with Keeloq® Hopping code
The unit is equipped with a superhetherodyne AM receiver with
Through the menu TX Management it is possible to manage the memory of the receiver which can store up to 50 transmitters.
Through the menu TX Management it is possible to manage the memory of the receiver which can store up to 50 transmitters.
MENU MAIN
Tx Management
If the set-up of the parameters hasn't been successful, it's possible to recover the factory settings using the sub-menu Factory defaults
If the set-up of the parameters hasn't been successful, it's possible to recover the factory settings using the sub-menu Factory defaults
from the Main menu. After the completion of this function, all the parameters will be reset to the factory value. See each function to know
from the Main menu. After the completion of this function, all the parameters will be reset to the factory value. See each function to know
the corresponding value
the corresponding value
Menu Main

Factory Defaults

Having reset the system to the factory settings, the operator can drive the door but without using the the acceleration and deceleration
Having reset the system to the factory settings, the operator can drive the door but without using the the acceleration and deceleration
values calculated during the Step III of Door Calibration. In order to revert to the previous operating mode it is necessary to repeat Step III
values calculated during the Step III of Door Calibration. In order to revert to the previous operating mode it is necessary to repeat Step III
again.
again.
The door limits ( DOOR CLOSE and DOOR OPEN ) remain the same.
The door limits ( DOOR CLOSE and DOOR OPEN ) remain the same.
The transmitters memory is completely erased.
The transmitters memory is completely erased.
It is possible to give a restart to the system, equivalent to a "power-off + power-on", using the option "System Reset" from the main menu.
It is possible to give a restart to the system, equivalent to a "power-off + power-on", using the option "System Reset" from the main menu.
After the system reset the LCD displays the sw release, the parameters condition and the free memory space for transmitters.
After the system reset the LCD displays the sw release, the parameters condition and the free memory space for transmitters.
This function doesn't change the value of any parameter except for the currents ( I and i ) which will be re-calculated during the next 2
This function doesn't change the value of any parameter except for the currents ( I and i ) which will be re-calculated during the next 2
cycles.
cycles.
MENU MAIN

System Reset

cdvi.com
20
cdvigroup.com
Remote controls management
Remote controls management
To memorize a transmitter, select
To memorize a transmitter, select ADD
Tx Management
press OK. At the message "PRESS TX BUTTON to ADD", press the button of
press OK. At the message "PRESS TX BUTTON to ADD", press the button of
ADD
the transmitter to memorize it . If everything is correct
the transmitter to memorize it . If everything is correct the
transmitter will appear on the LCD display. If the transmitter is already present in the
transmitter will appear on the LCD display. If the transmitter is already present in the
Press TX Button
memory,
memory, the following message will appear
to ADD
To delete a transmitter select the option REMOVE
To delete a transmitter select the option
Tx Management
REMOVE
and press OK. At the message "PRESS TX BUTTON to
and press OK.
of the transmitter to cancel.
of the transmitter to
appear on the LCD display.
appear
Press TX Button
to REMOVE
To completely erase the data base select the option REMOVE ALL
To completely erase the data base select the option
Tx Management
REMOVE ALL
MANAGEMENT and OK.
MANAGEMENT and OK. At the message
OK and the memory will be completely erased.
OK and the memory will be completely erased.
REMOVE ALL TX
from DATABASE?
Factory Defaults
Factory Defaults
Reset to Factory
Defaults?
Answer OK to proceed or ESC to exit without any action
Answer OK to proceed or ESC to exit without any action
Are you sure?
System Reset
System Reset
Confirm
System Reset?
Are you sure?
Keeloq® Hopping code security protocol.
security protocol.
ADD from the menu TX MANAGEMENT and
the following message will appear: TX ALREADY PRESENT.
At the message "PRESS TX BUTTON to REMOVE,
cancel. If everything is correct, the
If everything is correct, the message
on the LCD display.
At the message "REMOVE ALL TX from DATABASE, press
ATTENTION
ATTENTION : : This action also removes the 4-ch transmitter, used to
This action also removes the 4-ch transmitter, used to
navigate through the menu. The navigation will be possible only with the
navigate through the menu. The navigation will be possible only with the
buttons of the keyboard or after the memorization of a new 4-ch transmitter,
buttons of the keyboard or after the memorization of a new 4-ch transmitter,
in the fi rst memory location.
in the fi rst memory location.
from the menu TX MANAGEMENT and
the Serial Number of the
Serial Number of the
: TX ALREADY PRESENT.
REMOVE from the menu
from the menu TX MANAGEMENT
TX MANAGEMENT
REMOVE, press the button
press the button
message: : TX REMOVED