10. SCHEME OF EXAMINATION
GCE recommendations for a Written Scheme of Examination:
EQUIPMENT
EN
1. High pressure hoses
2. Pipe connections
3. Safety Relief Valve
4. Regulator
5. Non Return Valves
6. Valves
7. Alarm system
8. Filters

11. ACCESSORIES AND SPARE PARTS

Standard accessories are alarm and stabilizer (MM40 - STABILIZER or LINE REGULATOR).
Contact supplier of the system or GCE dealer for spare part lists. Use only GCE original spare
parts.
Use only GCE original spare parts!
12. CLEANING OF EXTERNAL PARTS
Remove dirt with a soft cloth damped in oil free oxygen compatible soap water and rinse with
clean water. If other cleaning solutions are used, check that they are not abrasive and that they
are compatible with: Cu, Fe, Al alloy, brass, plastic materials of components, labels and gas.
Do not use cleaning solutions containing ammonia!
Do not immerse in water or any liquid.
Do not clean electrical connections when the power is on. Make sure the connections are dry
before turning power back on.
13. LIFETIME, REPAIR AND DISPOSAL
13.1. LIFE TIME AND WASTE MANAGEMENT
The maximum life time of the product is 10 years at compliance of Examination schedule
(chapter 10). At the end of the product's life time, the product must be withdrawn from service.
The owner of the device shall prevent the reuse of the product and handle the product in
compliance with "Directive of European Parliament and Council 2008/98/EC on waste".
In accordance to Article 33 of REACH GCE, s.r.o. as responsible manufacturer shall inform all
customers if materials containing 0.1% or more of substances included in the list of Substance
of Very High Concern (SVHC).
The most commonly used brass alloys used for bodies and other brass components contain
2-3% of lead (Pb), EC no. 231-468-6, CAS no. 7439-92-1. The lead will not be released to the gas
or surrounding environment during normal use. After end of life the product shall be scrapped
by an authorized metal recycler to ensure efficient material handling with minimal impact to
environment and health.
EXAMINATION INTERVAL
Examine when changing cylinders. Replace every 5 years
1 year
1 year
1 year
1 year
1 year
Check when changing cylinders.
1 year