Accessories - Milwaukee M18 FORCELOGIC Manuel De L'utilisateur

Masquer les pouces Voir aussi pour M18 FORCELOGIC:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4. Screw the head onto tool (clockwise). Hand tighten
securely. Do not over tighten. The expander head
must fi t tightly against the tool.
5. Check installation:
Flowering
a. Ensure the head segments
segments
do not "fl ower".
b. Rotate the six expander
segments in the clockwise
direction. The head will rotate
freely. The head should not
rotate counterclockwise.
c. The expander head collar will
fi t fl ush against the tool.
d. Correct installation by loos-
ening the head slightly and
rotating the segments until
they engage in the cogs. Re-tighten the head.
OPERATION
Always remove battery pack before
WARNING
changing or removing accesso-
ries. Only use accessories specifi cally recom-
mended for this tool. Others may be hazardous.
To reduce the risk of injury, wear safety goggles
or glasses with side shields.
Use only MILWAUKEE M18™ Pro-
CAUTION
PEX
®
expander heads. The use of
incorrectly sized expansion heads may result in
faulty connections, which could result in prop-
erty damage.
Making PEX Tubing Connections
To ensure a proper connection:
• Remove the expander head and remove any dirt
and debris.
• Use a clean, lint-free cloth to apply a thin coat of
ProPEX
®
Expander Cone Grease to the expander
cone. Do not over or under-lubricate. Wipe excess
grease from inside collar and cone before expand-
ing tubing.
Improper lubrication (too much or
CAUTION
too little) may result in faulty con-
nections, which could result in property damage.
• Do not expand tubing beyond the tool's capacity
(3" / DN75).
1. Cut the PEX tubing to the needed length. Use only
cutters designed for plastic tubing. Make sure the
cut is perpendicular to the length of the tubing.
®
2. Slide the ProPEX
Ring over
the end of the tubing until it
butts aginst the ring stop.
3. With expander head NOT
tubing
inserted in the tubing, pull and
ring
hold the trigger to initiate the
rotation of the expander head.
Do not force the tubing onto the
CAUTION
expander head.
4. When the green indicator light
turns on and/or the white work
light flashes, insert the ex-
pander head into the PEX
tubing and release the trigger.
5. The expander head will con-
tinue to expand. When the expander reaches
maximum diameter it will automatically retract.
NOTE: To cancel quickly, pull and release trigger.
6. Tool will be fully retracted when green indicator
light blinks 3 times. The next expansion can be
started.
7. Continue expanding until the tubing reaches the
shoulder of the expander head. Then expand 1 to
2 more times, depending on the room temperature
(the warmer the temperature, the more expansions
are necessary).
Ensure the expander head rotates
CAUTION
at the beginning of each stroke to
ensure creation of even, smooth expansion
marks. If the head is not rotating, the expander
head may cause deep grooves in the tubing and
faulty connections, which could result in a leak.
Expansion
markings
inside tubing
Incorrect
Correct
8. Remove tubing when the segments are contracted.
9. Slide the tubing over the fi tting until it is fl ush with
the fi tting shoulder. If unable to slide tubing over
the fi tting, remove from fi tting and expand one
additional time. Important! You should feel some
resistance as the fi tting goes into the tubing If you
do not feel any resistance, the tubing may be over
expanded and will require additional time to shrink
over the fi tting .
10.Tubing should fi t tightly against the fi tting shoul-
der. If more than 1/16" gap between tubing and
shoulder, cut 3"-5" (3" for 2" PEX and 5" for 2.5"
and 3" PEX) off the end of the tubing and restart
the procedure with a new ProPEX
Status Indicator
LED
Indicates
Action
Flashing
Rotation
Insert into tubing and release
White
complete
the trigger
Solid Green Expansion
Tool will continue to expand to
in progress
maximum diameter
Flashing
Expansion
Start process for next
Green
complete
expansion
Flashing Red Expansion
Correct the error and restart
error
the expansion process
Flashing Red
Service
Contact a MILWAUKEE
and Green
required
service facility for ALL repairs.
Cold-weather Use
Colder weather (<40°F/4°C) requires a longer con-
traction time and fewer expansions.
Troubleshooting ProPEX
®
Connections
If fi ttings will not seal, check for the following:
1/16"
• Is the expander head screwed on tightly? Tighten
the head securely. Ensure the head is tight against
the tool.
• Are the expander head segments bent or mis-
aligned? Replace expander head.
• Are the expander head segments failing to contract
between expansions? Clean the head and lubricate
the cone. Ensure cogs are engaged.
Cogs
4
•Is the expander cone over or under lubricated?
Clean and lubricate.
• Is the fi tting damaged? Replace fi tting.
• Is the expander cone bent or damaged? Return to
a MILWAUKEE service facility for repair.
• Was the expander head held in the expanded posi-
tion before tubing was removed? Cut 3"-5" (3" for 2"
PEX and 5" for 2.5" and 3" PEX) off the end of the
tubing and restart the procedure with a new ProPEX
Ring.
• Was the tubing rotated slightly after each expan-
sion? Cut 3"-5" (3" for 2" PEX and 5" for 2.5" and
3" PEX) off the end of the tubing and restart the
procedure with a new ProPEX
• Are the tubing and ProPEX
Wipe dry.
• Is grease getting into the tubing from the expander
head? Wipe grease from tubing. Clean the expander
head, ensuring excessive amounts of grease are not
present on the head.
If ProPEX
®
Ring slides during expansion:
• Are the tubing and ProPEX
Wipe clean.
• Are your hands clean and dry? Wipe dry — oils from
your hands can lubricate the tubing and ProPEX
Ring.
• Are you holding the ring in place? Place your thumb
against the ring and hold in place during fi rst couple
of expansions.
If expander head does not expand when trigger is
®
Ring.
pulled:
• Verify that the expander head is fully retracted.
• Set tool on a work surface with the cone pointing up.
Pull the trigger and hold until the green light indicates
that the press cycle has started. Release the trigger
and then press and hold the manual retract button
until the motor stops (up to 1 minute). Repeat if
expander head still does not expand when trigger
is pulled.
If the head does not fully retract at the end of an
expansion:
• Press the manual release button to fully retract the
expander cone
• Remove the expander head from the tool and rein-
stall, verifying proper installation.
MAINTENANCE
To reduce the risk of injury, always
WARNING
unplug the charger and remove the
battery pack from the charger or tool before
performing any maintenance. Never disassemble
the tool, battery pack or charger. Contact a
MILWAUKEE service facility for ALL repairs.
Maintaining Tool
Keep your tool, battery pack and charger in good
repair by adopting a regular maintenance program.
Each month:
• Remove the expander head and
soak in degreasing agent to
remove grease from between
expander segments. Re-lubri-
cate head (expander head
collar groove, expander cone
mating surface).
• Wipe expander cone and rotate
collar with clean, dry, lint-free
cloth. Re-lubricate when com-
plete.
After six months to one year, depending on use,
return the tool, battery pack and charger to A
MILWAUKEE service facility for:
• Lubrication
• Mechanical inspection and cleaning (gears, spin-
dles, bearings, housing, etc.)
• Electrical inspection (battery pack, charger, motor)
• Testing to assure proper mechanical and electrical
®
operation
If the tool does not start or operate at full power with
a fully charged battery pack, clean the contacts on
the battery pack. If the tool still does not work prop-
erly, return the tool, charger and battery pack, to a
®
Ring.
MILWAUKEE service facility for repairs.
®
Ring clean and dry?
To reduce the risk of personal in-
WARNING
jury and damage, never immerse
your tool, battery pack or charger in liquid or
allow a liquid to fl ow inside them.
Clean dust and debris from charger and tool vents.
Keep tool handles clean, dry and free of oil or grease.
®
Ring clean and dry?
Use only mild soap and a damp cloth to clean the
tool, battery pack and charger since certain cleaning
agents and solvents are harmful to plastics and other
®
insulated parts. Some of these include gasoline,
turpentine, lacquer thinner, paint thinner, chlorinated
cleaning solvents, ammonia and household deter-
gents containing ammonia. Never use fl ammable or
combustible solvents around tools.
For repairs, return the tool, battery pack and charger
to the nearest service center.

ACCESSORIES

Always remove battery pack before
WARNING
changing or removing accesso-
ries. Only use accessories specifi cally recom-
mended for this tool. Others may be hazardous.
For a complete listing of accessories, go online to
www.milwaukeetool.com or contact a local distributor.
SERVICE - UNITED STATES
1-800-SAWDUST
Monday-Friday, 7:00 AM - 6:30 PM CST
www.milwaukeetool.com
or visit
Contact Corporate After Sales Service Technical
Support with technical, service/repair, or warranty
questions.
Email: metproductsupport@milwaukeetool.com
Register your tool at www.milwaukeetool.com...
• to receive important notifi cations regarding your
purchase
• to ensure that your tool is protected under the warranty
• to become a Heavy Duty club member
SERVICE - CANADA
Lubrication
areas
Milwaukee Tool (Canada) Ltd
1.800.268.4015
Monday-Friday, 7:00 AM - 4:30 PM CST
or visit www.milwaukeetool.ca
LIMITED WARRANTY
USA & CANADA
Every MILWAUKEE power tool (including cordless product – tool, battery pack(s)
- see separate & distinct CORDLESS BATTERY PACK LIMITED WARRANTY
statements & battery charger and Work Lights*) is warranted to the original
purchaser only to be free from defects in material and workmanship. Subject to
certain exceptions, MILWAUKEE will repair or replace any part on an electric
5
Cleaning
Repairs
(1.800.729.3878)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

2633-20

Table des Matières