English
Relocating the Proximity Switch
(Rotating Rack Models Only)
Date Code 1829 or older
NOTE: The last four digits in a ten digit numerical serial number
are the manufacturing date code.
Example: Serial number 9625061331 has a date code
of "1331" which indicates:
Units equipped with a rotating rack will require relocating the
proximity switch(es) after reversing the door(s).
The proximity switch signals the rack motor to stop when a
door is opened and to start when the door is closed. Follow
the steps listed below to move the proximity switch(es) to the
proper position after reversing the door(s). Unit requires one
switch per door.
1. Turn off the unit and unplug the unit from the power source.
2. Remove the four screws and top cover.
3. Remove the screw and nut securing the proximity switch
to the cabinet ceiling sheet. The screw is accessed from
inside the cabinet. Reinstall screw and nut into hole after
removing switch.
4. Cut the cable tie securing the proximity switch wires to
the wiring harness. Mark the two wires for reassembly
and unplug the wires from the proximity switch wire leads.
Route the wires to the opposite corner and reattach the
wires to the switch wire leads.
Orientation of
proximity switch
for control-side
door installations.
Form No. FDWDM-1019
1331
Week Thirty-One
Year 2013
Cover Screw
Proximity
Switch Nut
Proximity
Proximity
Switch
Switch
Screw
Screw
Relocating the Proximity Switch (one door, left-hinged installation shown)
NOTE: Make sure to install the proximity switch in the
orientation shown below for the specific installation
location. Incorrect orientation will result in malfunction
of the proximity switch.
5. Remove the screw and nut from the new mounting hole.
Secure the proximity switch to the mounting hole with
the screw and nut. Make sure to maintain proper switch
orientation when tightening the hardware.
6. Make sure wires do not interfere with the other components
inside the cabinet, then secure switch wires to wiring
harness with a cable tie (not supplied).
NOTE: On models equipped with two doors, it may be
necessary to move the air chamber to access the
proximity switch on the customer-side door. Drain all
water from the unit, remove the drain valve from inside
the cabinet, and remove the four screws securing the
air chamber assembly to the cabinet. Carefully move
the air chamber out of the way to access the proximity
switch. Reassemble after relocating switch.
7. Install the top cover and four screws.
8. Plug the unit into the proper power source.
9. Turn on the unit and test the operation of the proximity
switch(es) by making sure the rack rotates when the doors
are closed and stops rotating when a door is opened.
Proximity
Switch
Proximity switch(es)
should be installed
on the same side as
One switch per door.
9
INSTALLATION
Orientation of
proximity switch
for customer-side
door installations.
the door handle.