Technical Specifications; Electrical Wiring - Buffalo DM868 Mode D'emploi

Thermoplongeur portable
Masquer les pouces Voir aussi pour DM868:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Fault
Error message E01
Unit is not sitting in the water
is displayed
Water level is too low
LCD Display does
Thermal Protector has activated
not switch on

Technical Specifications

Model
Voltage
DM868
230V 50Hz

Electrical Wiring

This appliance is supplied with a 3 pin, moulded, BS1363 plug and lead, with a 13 amp fuse as standard.
The plug is to be connected to a suitable mains socket.
This appliance is wired as follows:
Live wire (coloured brown) to terminal marked L
Neutral wire (coloured blue) to terminal marked N
Earth wire (coloured green/yellow) to terminal marked E
This appliance must be earthed.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency
disconnection being required they must be readily accessible.
Compliance
The WEEE logo on this product or its documentation indicates that the product must
not be disposed of as household waste. To help prevent possible harm to human
health and/or the environment, the product must be disposed of in an approved and
environmentally safe recycling process. For further information on how to dispose of
this product correctly, contact the product supplier, or the local authority responsible for
waste disposal in your area.
BUFFALO parts have undergone strict product testing in order to comply with regulatory
standards and specifications set by international, independent, and federal authorities.
BUFFALO products have been approved to carry the following symbol:
All rights reserved. No part of these instructions may be produced or transmitted in any form or by any means, electronic,
mechanical, photocopying, recording or otherwise, without the prior written permission of BUFFALO.
Every effort is made to ensure all details are correct at the time of going to press, however, BUFFALO reserve the right to
DM868_ML_A5_v6_20180507.indb 7
Probable Cause
Power
Current
1500W
6.5A
change specifications without notice.
Solution
Make sure the unit is sitting in the water and
that the water level is between the MIN and
MAX line.
Add water, make sure the water level is
between the MIN and MAX line.
Reset Thermal Protector (Page 5).
Dimensions
h x w x d mm
320 x 145 x 130
UK
Weight
2.35Kg
7