UK
Cleaning, Care and Maintenance
•
Always turn Off the appliance and disconnect from the power supply before cleaning.
•
Allow the appliance to cool before cleaning.
•
The inner body of the appliance should be wiped down at the end of each day's operation. Additional
cleaning may be required depending on frequency of use.
•
Warm soapy water is recommended for cleaning. Cleaning agents may cause damage or leave harmful
residues when used for a prolonged period on stainless steel.
•
A BUFFALO dealer or qualified technician should carry out repairs if required.
Troubleshooting
If your BUFFALO Pie Warmer develops a fault, please check the following table before making a service call.
Fault
The unit is not heating
up and the green
indicator light is Off
The unit heats up but
the red indicator light is
Off
The unit is not heating
up or heats up slowly
and the indicator light is
On
Technical Specifications
Model
Voltage
Power
GF454
230
350W
50Hz
GF455
230,
650W
50Hz
3
Probable Cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Indicator light is faulty
Incorrect operation
Thermostat failure
Element failure
Dimensions
Current
h x w x d
(mm)
1.52A
500 x 595 x
390
2.85A
582 x 755 x
390
Check the unit is plugged in correctly and
switched on
Call BUFFALO agent or qualified technician
Replace the plug fuse
Check power supply
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Ensure:
•
thermostat has been set correctly
•
doors are closed
•
thermostat sensor bulb has not been
removed or damaged
Call BUFFALO agent or qualified technician
Call BUFFALO agent or qualified technician
Approx.
Weight
Pie
(kg)
Capacity
(to 90°C)
16
30
27 minutes
23
60
28 minutes
Action
Heat up
Operating
Time
Temperature
Range
30 - 90°C
30 - 90°C