Gas conversions from Natural gas to LP gas or from LP gas to
Natural gas must be done by a qualified installer.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.

LP Gas Conversion

WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
1. Turn manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
A
A. To range
B. Shutoff valve (closed position)
C. Gas supply line
22

GAS CONVERSIONS

To Convert Gas Pressure Regulator
1. Remove access panel by grasping sides and pulling upward,
2. Locate gas pressure regulator behind access panel.
3. Unscrew the regulator cap and remove the plastic cover.
4. Flip the regulator cap over and replace the plastic cover.
B
5. Screw the regulator cap securely back into place. Do not
C
lifting out.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
A. Plastic cover
B. Regulator cap
A
A. Natural gas position
B. LP gas position
overtighten.
A
B
B