4. Draw and cut a 6¼" (15.8 cm) diameter hole.
5. Position blower motor in cabinet opening and mount blower
motor to the floor.
A. Inlet from range
B. Exhaust outlet
6. Connect vent system to blower motor outlet with 4 - #8 x ¾"
hex head screws provided.
A
B
C
A. Inlet
B. Vent clamp
C. Floor
D. Vent system
7. Go to the "Electrical Connection" section.
14
Top View
B
A
D
Left or Right Side Venting
1. Mark cabinet side for either a left or right side vent hole
location.
A
B
A. 31³⁄₁₆" (79.2 cm) to top of cabinet
B. 18" (45.7 cm) from back wall
2. Mark and cut a 5½" (13.9 cm) diameter hole in the desired
cabinet side.
A. 5½" (13.9 cm) diameter hole
3. Mark and cut a 14" x 11" (35.6 x 27.9 cm) opening in the floor
of the same cabinet as the vent hole opening.
A
B
A. 11" (27.9 cm) from front of cabinet
B. 14" (35.6 cm) from left side of cabinet
A
Top View