OPTIONS AND ACCESSORIES
Stainless Steel Adjustable Legs
Stainless steel adjustable legs (P/N 05.30.070.00) are available
as accessories for all models.
Use the following procedure to install legs:
1. Carefully place unit on its side.
NOTICE
Do not lay unit on the side with the control panel or inlet
and outlet pipes. Damage to the unit could occur.
2. Thread the adjustable legs into the existing leg holes on
the bottom of the unit.
3. After all legs are secure, return the unit to the upright
position.
NOTE: If unit is not level, use an adjustable wrench to adjust
the foot of each leg until unit is level. Each leg is
adjustable from 6" (152 mm) to 7" (178 mm).
Adjustable
Foot
Stainless Steel Adjustable Legs
Floor Mounting Legs
Stainless steel adjustable legs with deck mounting flanges
secure the booster heater to the floor are available options for
Compact and Imperial models only.
Mounting Slide Brackets
A set of optional mounting slide brackets is available for
Compact models only. (P/N R04.20.030.00)
Plumbing Accessories
A shock absorber, a brass pressure reducing valve, and a back
pressure relief valve are available as accessories.
Shock Absorber
(P/N 03.40.057.00)
Brass Pressure
Reducing Valve
(P/N 03.02.015.00)
*Not available for Mini-Compact models.
Plumbing Accessories
Back Pressure
Relief Valve*
(P/N 03.02.039.00)
Blended Phosphate Water Treatment
System
The optional Blended Phosphate Water Treatment System
(P/N 03.05.061.00) dispenses a small amount of polyphosphate
into the water. The polyphosphate prevents the buildup of
mineral molecules.
The optional blended phosphate water treatment system is
installed with unions on the incoming 3/4" water supply line
after the pressure reducing valve and before the booster heater.
Replacing a Phosphate Cartridge
(P/N 03.05.061A.00)
Cartridges supplied have a usage rating of 100,000 gallons
(378,541 liters) of water. To ensure proper operation, the
cartridges must be replaced when the compound is near the
bottom of the cartridge.
Use the following procedure for replacement:
1. Move the ON/OFF (I/O) switch to the OFF (O) position.
2. Shut off water supply and open the drain valve to remove
water in piping.
3. Loosen the canister using the attached wrench.
4. Remove canister and discard depleted cartridge.
5. Using a clean damp cloth, wipe the interior of the canister
clean.
NOTE: Make sure the O-ring seal is placed properly in the
canister.
6. Reverse the above procedure to reinstall.
NOTE: Product failure caused by liming or sediment buildup is
not covered under warranty.
Canister
Blended Phosphate Water Treatment System
Stainless Body and Base
An optional stainless body and base is available for all models.
Stainless Tank
An optional stainless tank is available for compact models.
Security Package
A security package is a factory-installed option for Compact and
Imperial models only. A security package contains Torx
and a control cover.