Installation (Vent outside):
Attention! Observe the warning in the instruction sheet concerning the operation
of the appliance when air is discharged from the room.
When the range hood and appliance supplied with energy other than electricity
are simultaneously in operation, the negative pressure in the room must be not
exceed 4 Pa (4×10
Bar)
-5
9. Position the hanging plate on the ceiling and then mark the position of the screw
holes. The hanging plate should be securely fixed to the ceiling,
11 x ST6 x 40 mm screws for wooden ceiling (11 x wall plugs is optional, fix or not fix
are acceptable.)
8 x expansion bolts (M6*60) for cement ceiling
For wooden ceiling
For cement ceiling
Wall plugs
M6*60
10.Fix the angle bars to the hanging plate, using the 8 x M5 screws and nuts.
11.Extend the angle bars to the required height and then fix them in position using
the 16 x M5 screws and nuts with metal washers.
IMPORTANT: The angle bars must have an overlap of AT LEAST 100 mm.
IMPORTANT: The metal washers should be added in this step.( Washers 0.8*5.2*10,
16pcs.)
-37-