WARNING: follow the instructions of the boat engine manufacturer on how to connect engine
cooling liquid to the heat exchanger.
• Fit the stub pipe (11) to the valve (9) using hose clamp. Fit the pipe so as to allow any possible water
leak not to cause damage to part of the boat.
• Open up hot water taps of washbasins and start the water pump. This allows water to fill water heater
and force air out of water heater and pipes. Close taps as soon as air free water comes out.
• check that there are no leaks on pipe joints.
UNIT POWER SUPPLY
See fig.3 for the connection. Make sure the water heater operating voltage is the same as that provided
by AC network.
A double pole switch has to be included on the electric installation, in order to turn on and off the unit,
and a fuse of suitable rating. The insulation between connections contacts of the AC network must be at
least 3 mm. The connections to AC network must be done following the National Specifications on electri-
cal installations.
WARNING: before carrying out the connection make sure the cables are not live.
WARNING: don't operate the electric element if the tank is not filled with water. It may cause a
permanent damage to the electric element.
THERMOSTAT ADJUSTING
The standard temperature value of the thermostat is 60°C. If you wish to change it, follow the instructions
below:
• shut down power supply.
• Remove the protection cover (16) in order to reach the thermostat (14).
• Adjust the thermostat knob with a screwdriver (fig. 4) and turn it to the required temperature.
• Replace on the protection cover (16).
• Switch on power supply.