Slide the hoses over the nipples, pushing them right home and then fix them with appropriate tube nuts. Try to keep
both the suction and discharge hose as straight as possible, avoiding all unnecessary bends. Select the most appropriate injection
point on a pipe of the plant to be treated and there fit a 3/8" female steel gas thread connector (similar to BSPm). This connector
is not supplied with the pump. Screw the injection valve to the gas connector, inserting a gasket tape as Teflon. Then connect the
discharge hose to the conical connector on the injection valve and fix it with the supplied tube nut. The injection valve also acts
as no return valve by means of a cylinder sleeve.
EPOOL PH - RX
F eat u re s o f e Po o l
ePool is a friendly user equipment, made by a peristaltic pump and an electronic controller able to measure and settle the
chemical-physical values of a swimming pool, like the pH and the ORP (mV) values. The pump operate in proportional mode.
ePool pH factory defaults : Setpoint= 7,2 pH; intervention: ACID
ePool RX factory defaults : Setpoint= 700mV; intervention: OXIDANT
Co n t ro l s
1)
2)
3)
4)
5)
6)
Ala rm m ea su re L O W / HI GH
If the value of the measure is below 5 pH or higher of 9 pH, the display will show a message of error low or high
concentration of the acid in the swimming pool. For the REDOX the only type of dosification is only oxidant direction, so it is
possible only a low error for values of mV below 100.
St an d - b y
Press in the same time arrow up (1) and arrow down (2), (fig. 4).
P rim in g
With the pump in stand-by at the same time press MENU/ESC (3) and CAL/OK (4) (FIG.4).
Button to increase the value
Button to decrease the value
Button MENU/ESC
Button to CAL/OK
Button to set the stpoint7 segments display
Digital display
Fig. 4 – Pannello Comandi
ENGLISH
27