c) DMX Operation
Each DMX device in a DMX chain requires a so-called DMX starting address to be clearly identified by the
controller. This DMX starting address defines the first DMX channel to which the device responds. The
remaining control channels come after this first DMX channel (DMX starting address).
The device requires 3 DMX channels.
Setting the DMX starting address
Set the desired DMX start address in the menu item DMX512 (see menu overview) with the button UP or
DOWN.
The following table provides information about the effects of the settings on the individual DMX channels.
DMX channel
DMX Value
1
000-127
128-255
2
000-255
3
000-255
10. Handling
• Never connect the mains plug to a mains socket immediately after the device has been taken from a cold
to a warm environment. The resulting condensation may destroy the device.
Allow the device to reach room temperature before connecting it. Wait until the condensation has eva-
porated.
• Never pull the mains plug from the mains socket by the cable. Only pull it from the mains socket by the
intended grip areas.
• Unplug the mains adapter from the mains socket after use.
• Disconnect the mains plug from the mains socket during thunderstorms for reasons of safety.
• Never touch the device in operation or right afterwards, because this area heats up strongly particularly
in the area of the fog exit opening. There is a danger of burns.
• Never use contaminated fog liquids. Close the tank and the storage container for your fog liquid immedi-
ately after filling.
• Always empty the tank before transporting the device or if you are not using it for a longer period.
• Use only water-based fog liquid. Suitable fog liquids are listed in the „Technical Data" section.
26
Function
Fog emission off
Fog emission on
Fan speed 0-100 %
Fog volume setting 0-100 %