Sanyo CE42LM4N-NA Manuel D'utilisation page 8

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

RS232C settings
Thie monitor can be controlled via a RS232C from a computer
ITEM
Synchronous system
Transmission Speed
Data Length
Parity
Stop Bit
Flow Control
Serial Interface Specification
Transfer Specification
1. Transmission Speed: initial setting value is 19200
2. Transmission speed can be changed by hotel mode.
Connection
The Designated RS-232C serial cable, must be used for a
connection to a computer and LCD monitor
Notes for communication
PC
COM 1
1
CD
2
RXD
3
TXD
4
DTR
SG
5
6
DSR
7
RTS
8
CTS
9
RING
(D-Sub 9 Pin)
The monitor command is defined by one command/one line that
starts with "C" and ends with carriage return (0x0D)
There are two types of commands:
Functional Execution Command e.g Co5[CR] (table on page 33)
Status Read Commands e.g "CR0 [CR] (see table on page 33)
Setting the monitor address in RS232 mode
To Access hotel mode press the green button on the remote control
and hold for 5 seconds. A new screen will appear.
Hotel
Hotel mode
On program
Preset
Address
Baud Rate
: Select
Each monitor can have a specific Address for example 007, which
helps command that monitor individually and will not effect other
monitors connected to a controlling PC
Address format command
The addressing format command is used for operating multiple
monitor sets from a single PC via the RS232C command line. If you
set your monitor address to '000', it will never respond to any
addressing command from the PC.
If the address from the PC is 'FFF', all monitor sets will execute the
command.
The Address format command is defined by one command, one line
which starts with 'A' and ends with carriage return.(0 x0D).
The Monitor starts to decode when it receives a carriage return
(0x0D).
An address is added at the top of a control command (same as a
address command).
Example:
Functional execution command:
"A001C05" [CR] means address is 001 and the control command is
C05.
Status read command
"A001CR0"[CR] means address is 001 and command is CR0.
The monitor can set its own address in the hotel option menu
(above) The address range is 000 - 999, the default address will be
000.
The baud rate indicates the unit for transfer speed of data
from the PC to the monitor sets.
8
RS232 OPERA
RS232 OPERA
SPECIFICATION
Asynchronous
9600 / 19200
8 bit
None
1
None
TV CONTROL
PORT
1
N.C.
2
RXD
3
TXD
4
N.C
5
SG
6
N.C
7
RTS
8
CTS
9
N.C.
(D-Sub 9 Pin)
ON / OFF
AV1-AV3 /RGB/ HDMI/ PC
ON / OFF
007
19200
: Adjust
: Exit
MENU
TION/ OTHER FEA
TION/ OTHER FEA
■ Switching into/from standby mode
The Standby mode is used for switching the LCD monitor off for
short periods of time. In standby mode the monitor is switched
off but is still receiving mains power.
● To turn the monitor into standby mode, press the
The blue power indicator illuminates more brightly.
● To turn the display unit ON from standby mode, press any of
the following buttons:
■ Use of Audio Output Jacks
The audio monitor out sockets on the rear of the set provide a fixed
level audio output for reproducing sound via your audio equipment.
TURES
TURES
Other functions
4
5, 6
,
or 0-9 buttons.
If you find the power indicator flashing, disconnect
power cord from the power outlet and contact our
Service desk.
This warning is a sign to let you know that the power
protection function of this TV set is now operating.
4
button.
Serial
Port-IN

Publicité

Table des Matières
loading

Table des Matières