Dip switch
AUTOMATIC
1
CLOSING
2
2 / 4 STROKE
OPENING
3
PHOTOCELLS
OPERATION
NO
4
REVERSE
PRE-
5
FLASHING
PHOTOCELL
6
TEST
PEDESTRIAN
7
ENTRANCE
DEAD MAN'S
8
SWITCH
GATE
9
TYPE
OPENING
10
DIRECTION
SETUP
ENCODER
11
NOTE: moving DIP 11 from ON to OFF (or vice versa), learning process has to be
initialized again.
SENSITIVE
12
EDGE
OBSTACLE DETECTION
If the obstacle detection function (which can be set through trimmers FR and SENS) gets activated dur-
ing an opening manoeuvre, the gate closes approx. 20 cm., if it is activated during a closing manoeu-
vre, the gate opens fully.
WARNING: the control panel logics may interpret mechanical friction as an obstacle.
after opening, the gate automatically closes when the delay set on the
On
T.C.A. trimmer expires.
Off
automatic closing disabled.
with automatic closing enabled, a sequence of open/close commands
On
causes the gate to OPENCLOSE-OPEN-CLOSE etc (see also dip switch 4).
in the same conditions, the same command sequence causes the gate
Off
to OPEN-STOP-CLOSESTOP-OPEN-STOP (step-by-step).
during opening, cutting photocell stops the gate until the obstacle is
On
removed. When the obstacle is removed the gate resumes opening;
Off
during opening, the photocell does not cut in.
NO-REVERSE function activated; the gate ignores the closure commands
On
during opening; reversal of movement occurs only during closure;
the open-close pushbutton reverses the direction of movement of the
Off
gate even while it is opening.
On
pre-flashing function enabled.
Off
pre-flashing function disabled.
On
"photocell test" function is enabled;
"photocell test" function is disabled.
Off
Note: to be used when the photocells are not used.
the function changes to gate closing only. The contact N.A. 6-8 from
On
Pedestrian becomes Close (normally open contact)
Off
"open / close" Pedestrian function; (normally open contact)
Dead man's switch active for the OPEN and CLOSE keys (term. 4-8 and
On
6-8 with dip switch 7 in ON);
Off
Dead man's switch not active
On
settings for heavy gates or particularly difficult to open and close;
Off
settings for standard gates.
On
left-hand leaf opening function;
Off
right-hand leaf opening function;
ENCODER enabled: encoder obstacle detection function activated (use
On
the trimmers FR and SENS to adjust the sensitivity to obstacles);
Off
ENCODER disabled - obstacle detection disabled;
On
RESISTIVE SENSITIVE EDGE 8K2 Ohm (terminal no. 11);
Off
FIXED EDGE (NC contact – terminal no. 11).